Troubleshooting
If an alarm message appears in the display section or | unit appears to be malfunctioning, please check the | ||||
on the video monitor connected to this unit, or if the | following before contacting your Sony dealer. | ||||
Operation problems |
|
|
|
| |
|
|
|
|
| |
Symptom | Cause |
|
| Remedy | |
|
|
|
|
| |
The unit’s control buttons do | The KEY INHIBIT switch on the |
|
| Set the KEY INHIBIT switch on the subsidiary | |
not work. | subsidiary control panel is set to ON. | control panel to OFF. | |||
|
|
|
| ||
| The CONTROL PANEL switch on the | • Set the CONTROL PANEL switch on the | |||
| subsidiary control panel is set to EXT. | subsidiary control panel to INT. | |||
|
|
|
| • Set extended menu item 117 to PARA. | |
|
|
|
| ||
The unit’s transport control | The REMOTE button is lit and menu item | Turn off the REMOTE button and, on the | |||
buttons (PLAY, F FWD, REW, | 006 (LOCAL FUNCTION ENABLE) is set | subsidiary control panel, set the KEY INHIBIT | |||
etc.) do not work. | to ST&EJ or DIS.a) |
|
| switch and CONTROL PANEL switch to OFF and | |
|
|
|
| INT, respectively. | |
|
|
|
|
| |
| No cassette is loaded.a) |
|
| Insert a cassette. | |
|
|
|
|
| |
Tape problems |
|
|
|
| |
|
|
|
|
| |
Symptom | Cause |
|
| Remedy | |
|
|
|
| ||
Recording is not possible. | The cassette’s REC/SAVE switch is set | Set the REC/SAVE switch to REC, or use | |||
| to SAVE.a) |
|
| another cassette. | |
| The REC INHIBIT switch on the |
|
| Set the REC INHIBIT switch on the subsidiary | |
| subsidiary control panel is set to ON. | control panel to OFF. | |||
|
|
|
| ||
The NOT EDITABLE indication | The recording mode selected on this unit | • Set the unit for the same recording mode as with | |||
appears in the display section. | does not coincide with that of the loaded | the tape. | |||
| tape.a) |
|
| • When your current purpose is recording, you | |
|
|
|
| can use the tape currently loaded in the unit. | |
| The recording format of the currently | • You can use the currently loaded tape as a | |||
| loaded tape is DV or DVCPRO. |
|
| source tape for playback and editing. | |
|
|
|
| • You cannot use the tape as a recording tape for | |
|
|
|
| editing. | |
|
|
|
|
| |
Time data problems |
|
|
|
| |
|
|
|
|
| |
Symptom | Cause |
|
| Remedy | |
|
|
|
| ||
Cannot set the time data to an | The PRESET/REGEN switch on the | Set the PRESET/REGEN switch on the | |||
optional initial value. | subsidiary control panel is set to |
|
| subsidiary control panel to PRESET. | |
| REGEN.a) |
|
|
| |
|
|
|
| ||
| The counter value is selected as the time | Press the COUNTER SEL button to light the TC | |||
| data for display (the COUNTER indicator | (time code) or | |||
| is lit in the display section).a) |
|
| display section (the counter value cannot be | |
|
|
|
| preset). | |
|
|
|
|
| |
|
|
|
| Turn off the REMOTE button and, on the | |
|
|
|
| subsidiary control panel, set the KEY INHIBIT | |
|
|
|
| switch and CONTROL PANEL switch to OFF and | |
|
|
|
| INT, respectively. | |
|
|
|
| ||
The tape is running, but the | The HOLD button has been pressed. | Press the button once again to exit the time code | |||
time data does not appear in |
|
|
| preset mode. | |
the display section. |
|
|
|
| |
The | Press the COUNTER SEL button to light the | ||||
| |||||
| section.a) |
|
| COUNTER (counter value) or TC (time code) | |
|
|
|
| indicator in the display section. | |
|
|
|
|
| |
a) Inthesestates,alarmmessagesappearinthediaplaysectionandonthemonitorscreen. |
|
|
|
Troubleshooting and Maintenance 8 Chapter
Chapter 8 Maintenance and Troubleshooting | 137 |