Note

When you make settings for items 715 to 720, set the PROCESS CONTROL switch on the subsidiary control panel to MENU. When it is set to MENU, all controls on the subsidiary control panel are disabled.

Menu items in the 700s, relating to video control (continued)

 

Item number

Item name

 

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

729

CLOSED

Select whether to mute the closed caption signal to be superimposed on the 1st and

 

 

CAPTION BLANK

2nd fields of the output video signal.

 

 

(DSR-2000 only)

 

 

 

 

 

 

 

 

 

 

 

 

 

Sub-item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

FIELD 1

Select whether to mute the closed caption signal to be superimposed on the 1st field of

 

 

 

 

the output video signal.

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

: Do not mute.

 

 

 

 

ON: Mute.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

FIELD 2

Select whether to mute the closed caption signal to be superimposed on the 2nd field of

 

 

 

 

the output video signal.

 

 

 

 

 

 

 

 

: Do not mute.

 

 

 

 

OFF

 

 

 

 

ON: Mute.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Menu items in the 800s, relating to audio control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item number

Item name

 

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

801

DIGITAL JOG

 

Select whether to adjust the audio playback speed during slow playback.

 

 

SOUND

 

OFF: Do not adjust the audio playback speed.

 

 

 

 

 

 

 

 

 

 

 

 

 

: Adjust the audio playback speed.

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

802

DIGITAL AUDIO

 

Set the audio muting conditions during shuttle playback.

 

 

MUTE IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

: Not muted.

 

 

SHUTTLE MODE

 

 

 

 

CUEUP: Muted during cue-up or preroll operations.

 

 

 

 

 

 

 

 

 

 

FULL: Muted in shuttle mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

807

AUDIO OUTPUT

 

Select the output timing of an audio playback signal. The reference position corresponds

 

 

PHASE

 

to a setting of 80H; when the setting is less than 80H, the output timing is advanced,

 

 

 

 

 

and when it is higher than 80H, the output timing is delayed. (80H = 128 samples =

 

 

 

 

 

approx. 2.7 ms, 1 sample = approx. 20 µs)

 

 

 

 

 

0 ... 80 ... FF : Setting in this range.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

808

INTERNAL AUDIO

 

Select the operation of the internal audio test signal generator.

 

 

SIGNAL

 

SILNC: Silent signal.

 

 

GENERATOR

 

 

 

 

 

 

 

 

 

 

: 1-kHz, –20 dB FS sine wave signal.

 

 

 

 

 

1KHZ

 

 

 

 

 

When you select SG as the audio input in the input selection section of the upper control

 

 

 

 

 

panel, the audio test signal generated by the internal audio test signal generator is input.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

811

AUDIO

 

Select the audio reference level (headroom) for recording on tape.

 

 

REFERENCE

 

–12dB

 

 

LEVEL

 

 

 

 

–16dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–18dB

 

(factory default for DSR-2000P)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(factory default for DSR-2000)

 

 

 

 

 

–20dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Continued)

Menu Setup 6 Chapter

Chapter 6 Setup Menu 121