Max Model Setup
4.The cycle field is a 2 digit number. When the correct first numeral of the number displays, press the ENTER but- ton to save the number. The cursor automatically moves to the second number field.
NOTE: A leading zero (0) must be entered in the first field if the number of cycles is fewer than 10.
5.Press the ENTER button, to save the C1 information.
•If your G3 is equipped with more than one sensor input, you will automatically be prompted to begin selecting the pump control type for the
next sensor. Repeat steps 1 - 5 to program cycles for C2 and C3.
NOTE: If C / P2 and C / P3 are not used, the default OFF setting must be entered instead.
6.After you set the last field and press the ENTER button, the G3 saves the Cycle information and moves to setting Backup Time, page 34.
Pressure Control (P1, P2, P3) Setup
•For injector systems, monitoring pressure can be used as a way to ensure sufficient pressure has been reached to activate injectors. The pump runs, building up enough pressure to cause injectors to dispense fluid. Pressure continues to build to a pre- set maximum, activating the (user supplier) pres- sure switch. Then an external (user supplied) vent valve opens and pressure reduces, priming the injector for the next cycle.
•Pressure control is an ON / OFF selection only.
1.Use the UP or DOWN arrow button to toggle between OFF / C1/ P1.
2.When P1
displays, press
ENTER button to save selection.
3.If your G3 comes equipped with more than one sen- sor input, you will automatically be prompted to begin selecting pump control type for the next sen- sor. Repeat steps 1 - 2 to program P2 and P3.
If P1 / P2 / P3 is selected the vent valve time is automatically set to 5 minutes. If the unit is used in an injector based system and a sensor input is not used, the user must update the vent valve time in advanced programming. (See Advanced Program- ming,
Input Not Used
Select OFF if your system does not use the applicable input.
1.Use UP or DOWN arrow but- ton to toggle between OFF / C1 / P1 on the display.
2.When
OFF is on the dis-
play, press the
ENTER
button to save selection.
If the sensor inputs are available and none are used in the ON Mode, the definition of the entered time is ON TIME.
Examples:
Model
Model
Backup Time
In both Cycle and Pressure Modes, a maximum run Time (Backup Time) for the lubrication period must be set up. If this Time expires before the lubrication is com- pleted an alarm/warning is triggered and the pump stops.
32 | 332305B |