Operation / Data Log
Common Error Log entries are listed below.
Software Fault | An internal software error | |
| occurred. Contact Graco Cus- | |
| tomer Service. | |
|
| |
Low Level Warning | The unit entered a low level | |
| warning mode and is running | |
| low on material. The pump | |
| continues to dispense material | |
| for the duration of the low level | |
| alarm time specified by the | |
| unit. | |
|
| |
Low Level Fault | The alarm time in low level | |
| warning has elapsed. The unit | |
| will not pump until the reservoir | |
| is filled and the fault is cleared. | |
|
| |
Cycle 1 Not Detected | In a divider valve system, the | |
| system has not received the | |
Cycle 2 Not Detected | ||
programmed number of divider | ||
| ||
Cycle 3 Not Detected | ||
valve cycles for the specified | ||
| ||
| input in the programmed | |
| backup time. | |
|
| |
Pressure 1 Not | In an injector system the sys- | |
Detected | tem has not received a signal | |
| from the pressure switch in the | |
Pressure 2 Not | ||
designated backup time. | ||
Detected | ||
| ||
|
| |
Pressure 3 Not |
| |
Detected |
| |
|
| |
System Already Pres- | In an injector system the pres- | |
surized 1 | sure switch is activated when | |
| the unit enters a pump on | |
System Already Pres- | ||
surized 2 | mode and may not have | |
vented properly. | ||
| ||
System Already Pres- | ||
surized 3 |
| |
|
| |
Machine Count Sensor | The specified number of | |
Failure | machine count input activa- | |
| tions was not received within | |
| the designated backup time. | |
|
| |
Motor Overcurrent | The unit is out of expected | |
| motor current range. Check the | |
| system to determine that it is | |
| functioning correctly (i.e., no | |
| blocked lines). Continued oper- | |
| ation at excessive motor cur- | |
| rents will cause degradation in | |
| pump life. | |
|
|
High Temperature | Internal temperature of the unit |
Warning | is above the designated oper- |
| ating. Check the unit and sys- |
| tem to determine that it is |
| functioning correctly. Operating |
| outside of the specified tem- |
| perature range may cause |
| reduced performance and pos- |
| sible unit failure. |
|
|
Low Temperature | Internal temperature of the unit |
Warning | is below the designated operat- |
| ing. Check the unit and system |
| to determine that it is function- |
| ing correctly. Operating outside |
| of the specified temperature |
| may cause reduced perfor- |
| mance and possible unit fail- |
| ure. |
|
|
USB Unable to Mount | The USB flash drive that was |
| installed was unable to connect |
| and communicate with the |
| pump. |
|
|
USB Unsupported | The USB flash drive is unsup- |
Device | ported. Use a different flash |
| drive. |
|
|
USB File Not Found | The pump program setting file |
| was not found or created cor- |
| rectly. Restore the setting file |
| to the flash drive. |
|
|
USB Folder Navigation | The pump program setting file |
| was not found or created cor- |
| rectly. Restore the setting file |
| to the flash drive. |
|
|
USB Invalid File | The pump program settings file |
| was not found or created cor- |
| rectly. Restore the setting file |
| to the flash drive. |
|
|
Failed Pin Code Entry | A failed attempt was made to |
| enter the pin code password. |
|
|