Operation / Data Log

Common Error Log entries are listed below.

Software Fault

An internal software error

 

occurred. Contact Graco Cus-

 

tomer Service.

 

 

Low Level Warning

The unit entered a low level

 

warning mode and is running

 

low on material. The pump

 

continues to dispense material

 

for the duration of the low level

 

alarm time specified by the

 

unit.

 

 

Low Level Fault

The alarm time in low level

 

warning has elapsed. The unit

 

will not pump until the reservoir

 

is filled and the fault is cleared.

 

 

Cycle 1 Not Detected

In a divider valve system, the

 

system has not received the

Cycle 2 Not Detected

programmed number of divider

 

Cycle 3 Not Detected

valve cycles for the specified

 

 

input in the programmed

 

backup time.

 

 

Pressure 1 Not

In an injector system the sys-

Detected

tem has not received a signal

 

from the pressure switch in the

Pressure 2 Not

designated backup time.

Detected

 

 

 

Pressure 3 Not

 

Detected

 

 

 

System Already Pres-

In an injector system the pres-

surized 1

sure switch is activated when

 

the unit enters a pump on

System Already Pres-

surized 2

mode and may not have

vented properly.

 

System Already Pres-

surized 3

 

 

 

Machine Count Sensor

The specified number of

Failure

machine count input activa-

 

tions was not received within

 

the designated backup time.

 

 

Motor Overcurrent

The unit is out of expected

 

motor current range. Check the

 

system to determine that it is

 

functioning correctly (i.e., no

 

blocked lines). Continued oper-

 

ation at excessive motor cur-

 

rents will cause degradation in

 

pump life.

 

 

High Temperature

Internal temperature of the unit

Warning

is above the designated oper-

 

ating. Check the unit and sys-

 

tem to determine that it is

 

functioning correctly. Operating

 

outside of the specified tem-

 

perature range may cause

 

reduced performance and pos-

 

sible unit failure.

 

 

Low Temperature

Internal temperature of the unit

Warning

is below the designated operat-

 

ing. Check the unit and system

 

to determine that it is function-

 

ing correctly. Operating outside

 

of the specified temperature

 

may cause reduced perfor-

 

mance and possible unit fail-

 

ure.

 

 

USB Unable to Mount

The USB flash drive that was

 

installed was unable to connect

 

and communicate with the

 

pump.

 

 

USB Unsupported

The USB flash drive is unsup-

Device

ported. Use a different flash

 

drive.

 

 

USB File Not Found

The pump program setting file

 

was not found or created cor-

 

rectly. Restore the setting file

 

to the flash drive.

 

 

USB Folder Navigation

The pump program setting file

 

was not found or created cor-

 

rectly. Restore the setting file

 

to the flash drive.

 

 

USB Invalid File

The pump program settings file

 

was not found or created cor-

 

rectly. Restore the setting file

 

to the flash drive.

 

 

Failed Pin Code Entry

A failed attempt was made to

 

enter the pin code password.

 

 