Graco 332305B important safety instructions Programming ON Duration, Cycle C1, C2, C3 Setup

Models: 332305B

1 76
Download 76 pages 7.83 Kb
Page 31
Image 31
Programming ON Duration

Max Model Setup

The first programmable number of the HH (hour) filed blinks, indicating the device is ready to program the first digit of the hour.

When programming a time of less then 12 hours, you must program a leading zero in the first number field and press the ENTER button to save the zero.

1.Use the UP and DOWN ARROW buttons to move up and down through the numbers 0-2 until the desired number appears in the first hour (HH) field.

2.Press the ENTER button to set the number.

3.Use the UP and DOWN ARROW buttons to move up and down through the numbers 0-9 until the desired number for the second HH number field appears.

4.Press the ENTER button to set the number.

5.The next number field to the right blinks and the LED under the MM lights indicating the G3 is ready to program the minutes fields.

6.Repeat steps 1-4 to set the minutes (MM) fields.

7.After pressing the ENTER button to set the time, the programmed Time information is saved.

Programming ON Duration

OFF, C1 (C2, C3) or

P1 (P2, P3) displays, identifying the func- tion you are program- ming.

Selection of OFF, C1 (C2, C3) or P1 (P2, P3) desig- nates the way pump run time is controlled:

C1, C2, C3 - Completing a specific number of cycles measured by an external prox/cycle switch

P1, P2, P3 - Reaching a specific pressure threshold measured by an external pressure switch - OR,

OFF - A specific duration of time elapses.

The LED next to C/P1 lights, indicat- ing which sensor of the pump control you are programming using either a specific number of cycles or by mon- itoring a pressure switch.

C / P2 and C / P3 controls functions to the second and third sensors (when sensors are used).

Only sensor inputs that are available on the unit can be programmed.

NOTE: Field cannot be left blank. If C / P2 and C / P3 are not used, OFF must be entered instead.

Cycle (C1, C2, C3) Setup

Cycle controls the number of lube cycles (as monitored by an external cycle monitor) completed before the pump rests.

NOTE:

You must program at least one cycle. Zero is not an available option.

1.Use UP or DOWN arrow but- ton to toggle display between OFF / C1 / P1 on the display.

2.When C1 is on display,

press the

ENTER

button to save selec-

tion and begin programming Cycle data.

The first number

displayed after the “C1” on the dis- play blinks, indi- cating the device is ready to pro-

gram the number of C1 cycles.

The LED under the

# sign lights when setting the number of cycles.

3.Program the number of cycles by pressing the UP or DOWN ARROW button to move up or down through number 0-9.