System Configuration and Wiring
. Improper installation of the grounding conductor may result in a risk of electric shock. This product must be installed by a qualified electrician in compliance with all state and local codes and regulations.
If the product is permanently connected:
•it must be installed by a qualified electrician or ser- viceman.
•it must be connected to a grounded, permanent wir- ing system.
If an attachment plug is required in the end use application:
•it must be rated for the product electrical specifica- tions.
•it must be an approved,
•it must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
•when repair or replacement of the power cord or plug is required, do not connect the grounding wire to either flat blade terminal.
Installation
Fuses
NOTICE
Fuses (user supplied) are required on all DC mod- els. To avoid equipment damage:
•Never operate G3 Pump DC models without a fuse installed.
•A fuse of the correct voltage must be installed in line with the power entry to the system.
Fuse Kits are available from Graco. The following Table identifies the correct fuse to use for your input voltage and the corresponding Graco Kit number.
Input Voltage | Fuse Value | Graco Kit No. |
|
|
|
12 VDC | 7.5 A | 571039 |
|
|
|
24 VDC | 4 A | 571040 |
|
|
|
Recommendations for Using Pump in Harsh Environments
•Use pump with CPC style power cable.
•If using a DIN style power or alarm harness with a right angle mating connector, make sure the con- nector does not exit the unit in the UP direction.
•Use a corrosion preventative electrical grease on all contacts.
332305B | 11 |