Advanced Programming

Advanced Programming

There are 7 Advanced Programming options. The following Table Identifies each option and when it is used.

Advanced

Model

Setting

Format/ Description

Why Use This?

Option

 

 

 

 

 

 

 

 

 

A1

Max

Lockout

Secures setup modes with

Prevents unauthorized users to adjusting

 

 

Code

PIN

settings.

 

 

(Optional)

 

 

A2

Max

Low Level

MM:SS (minutes:seconds)

To accommodate most lubrication situa-

 

 

Alarm Time

sets amount of time

tions, a conservative amount of time is pro-

 

 

 

between Low Level Warning

grammed between the low level warning

 

 

 

to Low Level Fault.

and fault to help protect unit from running

 

 

 

Default = 3 minutes

dry. If necessary the amount of time the

 

 

 

 

unit runs before stopping due to a low level

 

 

 

 

fault can be adjusted.

A3

Max

Vent Valve

MM:SS (minutes:seconds)

• In an injector based system that does not

 

 

Time

sets amount of time vent

use a sensor for feedback, determines

 

 

 

valve stays open after Pump

the amount of time the system vents.

 

 

 

ON Mode.

• Vent time can be modified.

 

 

 

Default = 5 minutes

 

A4

Max

Alarm Retry

Sets number of automatic

Establishes the number of times the unit

 

 

 

retries after a Cycle or Pres-

automatically retries lubricating after a

 

 

 

sure Alarm.

cycle or pressure alarm to determine if a

 

 

 

Default = 0

temporary or false signal can be cleared.

 

 

 

 

A5

Max

Active

Changes alarm output

Uses alarm output to determine if a unit has

 

 

Alarm

behavior.

an alarm AND/OR loses power.

 

 

 

Default = OFF

The output turns ON when power is

 

 

 

 

applied. It turns OFF when power is lost or

 

 

 

 

an alarm occurs.

 

 

 

 

Normal operation (OFF) will only activate

 

 

 

 

alarm output in an alarm condition when

 

 

 

 

power is on.

 

 

 

 

Can change (set to ON) to activate alarm

 

 

 

 

with power ON and deactivate with power

 

 

 

 

OFF OR warning.

 

 

 

 

Used to manage power outage.

A6

DMS

Functional

Clears the Functional and

Allows user to track lube events from a spe-

 

Equipped

and Techni-

Technical User Summaries

cific point (reset), i.e. a month to month

 

Models

cal User

 

evaluation.

 

 

Summary

 

 

 

 

Reset

 

 

A7

Max

Constant

Changes alarm output

This function changes the behavior of the

 

 

Alarm Out-

behavior.

alarm output in a fault from either toggling

 

 

put on Fault

Default = OFF

once every second or steady on.

 

 

 

 

332305B

45

Page 45
Image 45
Graco 332305B important safety instructions Advanced Programming, Pin