Advanced Programming
Advanced Programming
There are 7 Advanced Programming options. The following Table Identifies each option and when it is used.
Advanced | Model | Setting | Format/ Description | Why Use This? | |
Option | |||||
|
|
|
| ||
|
|
|
|
| |
A1 | Max | Lockout | Secures setup modes with | Prevents unauthorized users to adjusting | |
|
| Code | PIN | settings. | |
|
| (Optional) |
|
| |
A2 | Max | Low Level | MM:SS (minutes:seconds) | To accommodate most lubrication situa- | |
|
| Alarm Time | sets amount of time | tions, a conservative amount of time is pro- | |
|
|
| between Low Level Warning | grammed between the low level warning | |
|
|
| to Low Level Fault. | and fault to help protect unit from running | |
|
|
| Default = 3 minutes | dry. If necessary the amount of time the | |
|
|
|
| unit runs before stopping due to a low level | |
|
|
|
| fault can be adjusted. | |
A3 | Max | Vent Valve | MM:SS (minutes:seconds) | • In an injector based system that does not | |
|
| Time | sets amount of time vent | use a sensor for feedback, determines | |
|
|
| valve stays open after Pump | the amount of time the system vents. | |
|
|
| ON Mode. | • Vent time can be modified. | |
|
|
| Default = 5 minutes |
| |
A4 | Max | Alarm Retry | Sets number of automatic | Establishes the number of times the unit | |
|
|
| retries after a Cycle or Pres- | automatically retries lubricating after a | |
|
|
| sure Alarm. | cycle or pressure alarm to determine if a | |
|
|
| Default = 0 | temporary or false signal can be cleared. | |
|
|
|
| ||
A5 | Max | Active | Changes alarm output | Uses alarm output to determine if a unit has | |
|
| Alarm | behavior. | an alarm AND/OR loses power. | |
|
|
| Default = OFF | The output turns ON when power is | |
|
|
|
| applied. It turns OFF when power is lost or | |
|
|
|
| an alarm occurs. | |
|
|
|
| Normal operation (OFF) will only activate | |
|
|
|
| alarm output in an alarm condition when | |
|
|
|
| power is on. | |
|
|
|
| Can change (set to ON) to activate alarm | |
|
|
|
| with power ON and deactivate with power | |
|
|
|
| OFF OR warning. | |
|
|
|
| Used to manage power outage. | |
A6 | DMS™ | Functional | Clears the Functional and | Allows user to track lube events from a spe- | |
| Equipped | and Techni- | Technical User Summaries | cific point (reset), i.e. a month to month | |
| Models | cal User |
| evaluation. | |
|
| Summary |
|
| |
|
| Reset |
|
| |
A7 | Max | Constant | Changes alarm output | This function changes the behavior of the | |
|
| Alarm Out- | behavior. | alarm output in a fault from either toggling | |
|
| put on Fault | Default = OFF | once every second or steady on. | |
|
|
|
|
332305B | 45 |