Graco 332305B DMS Models Only, Storing Pump Program Settings to the Flash Drive, Downloading Data

Models: 332305B

1 76
Download 76 pages 7.83 Kb
Page 37
Image 37
DMS™ Models Only

flashes and the LED lights under SS; indicating it is ready to program the seconds fields.

5.Repeat steps 1 - 4 to set the SS (seconds) fields.

6.After pressing the ENTER button to set the last SS field the G3 automatically switches to the RUN MODE.

DMSModels Only

Downloading Data

1. Plug the USB flash drive into the USB port.

NOTE: The G3 pump stops pumping as soon as the USB flash drive is plugged into it.

2.The system automatically begins downloading data to the USB drive.

3.“data” is displayed while the system

is downloading files.

4. When download is finished, “done” is displayed.

5.G3 pump restarts cycle in the OFF mode.

6.Remove the USB flash drive.

Storing Pump Program Settings to the Flash Drive

The pump program settings file is named:

GRACO/G3Config/g3config.bin. This file cannot be modified. Modification of the file or file name may cause it to be unusable.

1. Plug the USB flash drive into the USB port.

NOTE: The G3 pump stops pumping as soon as the USB flash drive is plugged into it.

2.The system automatically begins downloading data to the USB drive.

3.“data” is displayed while the system

is downloading files.

4. When download is finished, “done” is displayed.

Max Model Setup

5.G3 pump restarts cycle in the OFF mode.

6.After the download is com- plete, press and hold the UP and DOWN ARROW button for 3 seconds to store the cur- rent setup to the USB flash drive.

7.“data” is displayed while the unit is downloading and storing the configu- ration on the USB drive.

8.When configuration is stored, “done”

is displayed.

9.G3 pump restarts cycle in the OFF mode.

10.Remove the USB flash drive.

Uploading Pump Program Settings to the Pump

1. Plug the USB flash drive into the USB port.

NOTE:

The USB flash drive must contain file GRACO/G3Config/g3config.bin.

The G3 pump stops pumping as soon as the USB flash drive is plugged into it.

2.The system automatically begins downloading data to the USB drive.

3.“data” is displayed while the system

is downloading files.

4. When download is finished, “done” is displayed.

5.G3 pump restarts cycle in the OFF mode.

6.After the download is com- plete, press and hold the RESET button and UP ARROW button for 3 seconds

to upload the setup stored in the USB flash drive.

7.“data” is displayed while the unit is

uploading the configuration data.

8. When upload is finished, “done” is displayed.

332305B

37

Page 37
Image 37
Graco 332305B DMS Models Only, Storing Pump Program Settings to the Flash Drive, Downloading Data