Graco 332305B important safety instructions PUMP OFF / REST Setup, Machine Count, Backup Time

Models: 332305B

1 76
Download 76 pages 7.83 Kb
Page 34
Image 34
PUMP OFF / REST Setup

Max Model Setup

2.Press the ENTER button to lock in the selection. The next MM number field to the right flashes indicating it is ready for programming.

3.Use the UP or DOWN ARROW button to scroll through numerals 0 to 9 until the desired number appears in the second MM number field.

4.Press the ENTER button to lock in the selection.

The next number field to the right

flashes and the LED lights under SS; indicating it is ready to program the seconds fields.

5.Repeat steps 1 - 4 to set the SS (seconds) fields.

6.After pressing the ENTER button to set the last SS field, all the programmed ON Time information is saved.

The G3 automatically switches to the OFF Time

SETUP MODE.

PUMP OFF / REST Setup

After setting the parameters for either Cycle (C1, C2 or C3) or Pressure (P1, P2, or P3) ON modes, the OFF or pump rest cycle must be set up. There are 3 ways to control this function:

Machine Count switch activation, or

Machine Count activations limited by a maxi- mum Time, or

A specific set amount of Time (similar to Time Mode).

If the machine count sensor input is available and not used in the OFF Mode, the definition of the entered time is OFF TIME.

Machine Count

1.After you set the last ON Time field and press the ENTER button, the G3

automatically switches to the Machine Count setup.

Notice the LED next to 123 on the G3 display lights

indicating you are now in the Machine Count setup mode.

2.Press the UP or DOWN ARROW button to move up or down through number 0-9.

3.When the correct number displays, press the ENTER button to set the num- ber.

NOTE: If the machine count input is available on the unit and not used, the value MUST be set to zero (0).

4. Repeat 2 - 3 to set the remaining fields.

NOTE: After the Machine Count value is entered, the G3 can be programmed to backup the machine count input with time.

Backup Time Setup

1. The OFF Time LED lights.

OFF displays.

2.Press the UP or DOWN ARROW button to change OFF to ON on the display.

3.Press the ENTER button to set the selection.

Backup Time

The LED next to the clock in the OFF field lights, indicating you are setting the Backup Time parameters.

OFF Time is set in Hours and Minutes (HH: MM).

34

332305B

Page 34
Image 34
Graco 332305B important safety instructions PUMP OFF / REST Setup, Machine Count, Backup Time