Alarms

Low Level Fault

HH MM SS ##

ON OFF

MM : SS HH : MM

CP 1

 

 

CP 2

C

1 2 3

CP 3

P

 

!

Level of lubricant in reservoir is low and addi- tional lubricant needs to be added.

Unit stops pumping and displays amount of accu- mulated time since the alarm was triggered.

Add lubricant to reservoir.

After lubri- cant is added press and hold the

RESET button to clear fault.

If repriming pump is required, the low level alarm time should be decreased. See A-2: Advanced Programming, Low Level Alarm Time page 47.

Cycle /

Pressure

Warning

HH MM SS ##

ON OFF

MM : SS HH : MM

CP 1

 

 

CP 2

C

1 2 3

CP 3

P

 

!

System fails to relieve pressure or a lubrication cycle was not completed in the user-defined amount of time.

Unit will continue to oper- ate for the number of lubri- cation cycles set by the warning retry parameter (see Advanced Program- ming, page 45).

If the warning condition clears itself on the next automatic lubrication cycle, the warning is cleared and the unit continues normal operation.

Examine system to deter- mine if you have a plugged or broken line or other component failure, i.e., divider valve, injector.

Press the RESET but- ton to clear warning.

58

332305B

Page 58
Image 58
Graco 332305B important safety instructions Low Level Fault, Cycle Pressure