Graco 332305B Changing Greases, Models without a follower plate, Models with a follower plate

Models: 332305B

1 76
Download 76 pages 7.83 Kb
Page 25
Image 25
Models without a follower plate:

Models without a follower plate:

1. Connect fill hose to inlet fitting (FIG. 16).

E

D

FIG. 16

2.For higher viscosity fluids, start pump to rotate stir- ring paddle during fill to prevent air pockets from forming in grease.

To start the pump press the manual run button.

3.Fill reservoir with NLGI grease to max fill line.

NOTE: Vent port, located in rear of reservoir, should not be used as an overfill port/indicator.

max fill line

FIG. 17

4. Remove fill hose.

Models with a follower plate:

1.Connect fill hose to inlet fitting (FIG. 16).

2.For higher viscosity fluids, start pump to rotate stir- ring paddle during fill to prevent air pockets from forming in grease.

Setup

To start the pump press the manual run button.

3.Fill reservoir with grease until seal of

follower plate breaches the vent hole (FIG. 18) and the majority of air is expelled from the reservoir.

vent holeModels with a follower plate:

FIG. 18

NOTE: Vent port, located in rear of reservoir, should not be used as an overfill port/indicator.

4. Remove fill hose.

Changing Greases

When changing greases, always use compatible fluids or greases.

332305B

25

Page 25
Image 25
Graco 332305B important safety instructions Changing Greases, Models without a follower plate, Models with a follower plate