Models without a follower plate:

1. Connect fill hose to inlet fitting (FIG. 16).

E

D

FIG. 16

2.For higher viscosity fluids, start pump to rotate stir- ring paddle during fill to prevent air pockets from forming in grease.

To start the pump press the manual run button.

3.Fill reservoir with NLGI grease to max fill line.

NOTE: Vent port, located in rear of reservoir, should not be used as an overfill port/indicator.

max fill line

FIG. 17

4. Remove fill hose.

Models with a follower plate:

1.Connect fill hose to inlet fitting (FIG. 16).

2.For higher viscosity fluids, start pump to rotate stir- ring paddle during fill to prevent air pockets from forming in grease.

Setup

To start the pump press the manual run button.

3.Fill reservoir with grease until seal of

follower plate breaches the vent hole (FIG. 18) and the majority of air is expelled from the reservoir.

vent hole

FIG. 18

NOTE: Vent port, located in rear of reservoir, should not be used as an overfill port/indicator.

4. Remove fill hose.

Changing Greases

When changing greases, always use compatible fluids or greases.

332305B