Operation / Data Log

During operation the G3 Pump stores information as Log and Summary Files.

Logs contain the following information:

Log Name

DMS ID Number

Current Software Graco Part Number

Current Software Version

Date and Time of Upload

System Event Log

The System Event Log lists the date and time of the last 800 common system events such as pump cycles, man- ual run and setting changes. The most recent event is listed first.

The log file is stored in a folder structure created by the pump DMS ID and download date. If multiple downloads are done on the same date, the existing files will be writ- ten over.

The folder structure is as follows:

GRACO/G3_{DMS_id}/{download date - YYYYm- mDD}/EVENTLOG.CSV

Example: GRACO/G3_00025/20100911/EVENT- LOG.CSV.

Operation / Data Log

Sample System Event Log

Example Event Log 1: Pump cycle of a divider valve system with a proximity switch set to detect 5 divider valve cycles.

G3 System Event Log

DMS ID Number: 0025 (see page 38)

Software Part Number: 16F821

Software Version: 1019 09/29/2010 14:1400

Date

Time

Description

9/29/2010

14:13:02

Pump Run Off

9/29/2010

14:13:02

C1

Cycle Completed

9/29/2010

14:12:39

C1

Cycle Detected

9/29/2010

14:12:34

C1

Cycle Detected

9/29/2010

14:12:28

C1

Cycle Detected

9/29/2010

14:12:23

C1

Cycle Detected

9/29/2010

14:12:17

Pump Run On

332305B