Advanced Programming

To set Vent Valve Time:

NOTE:

The LED next to the clock in the OFF field lights and P1, P2, and P3, indi- cating the Vent Valve Time is being programmed.

7.After pressing the ENTER button to set the last seconds field, all the pro- grammed Time information is saved.

Unit exits Advanced Programming.

Time is set as minutes and seconds (MM:SS) only.

The small flashing

LED under the MM indicates you are setting Minutes.

The first field (left

side of display) blinks indicating the device is ready for you to begin programming.

When programming a time of less then 10 minutes you must program a leading zero in the first number field and press the ENTER button to save the zero selection.

1.To set the Time use the UP or DOWN ARROW but- ton to scroll through numerals 0 to 5 until the desired number appears in the first minute field.

2.Press the ENTER button to lock in the selection. The next minute field to the right flashes indicating it is ready for programming.

3.Use the UP or DOWN ARROW button to scroll through numerals 0 to 9 until the desired number appears in the second minute field.

4.Press the ENTER button to lock in the selection.

5.The next number field

to the right flashes and the LED lights under SS; indicating it is ready to program the Seconds fields.

6. Repeat steps 1 - 4 to set the MM (seconds) fields.

A-4 Alarm Retry

Programs the number of times G3 will automatically retry running a lubrication cycle after a cycle or pressure alarm activates. The default setting is 0. For assistance determining a reasonable number of Alarm Retries to program for your application, contact Graco Customer Service or your local Graco distributor.

1, 2, and 3 and Fault LED’s illuminate.

FIG. 24

To set the Alarm Retry:

1. The default value

0000 appears in the display.

2.Press the UP or DOWN ARROW button to move up or down through number 0-9.