Technical Data
Technical Data
AMaximum Working Pressure | 5100 psi (35.1 MPa, 351.6 bar) |
Power |
|
88 - 264 VAC; 0.8 A current, 90 VA Power, 47/63 Hz, | |
| Single phase, inrush/locked rotor, max 40A (1ms) |
12 VDC | 9 - 16 VDC; 5 A current, 60 W, inrush/locked rotor 12 A |
24 VDC | 18 - 32 VDC; 2.5 A current, 60 W, inrush/locked rotor 6 A |
Outputs - Alarm Relay |
|
Rated Load | Resistive: 0.4 A at 125 VAC, 2 A at 30 VDC |
| Inductive: 0.2 A at 125 VAC, 1 A at 30 VDC |
Max Operation Voltage | Resistive: 250 VAC, 220 VAC |
| Inductive: 250 VAC, 220 VDC |
Max Operating Current | Resistive: 3 A (AC), 3A (DC) |
| Inductive: 1.5 A (AC), 1.5 A (DC) |
Max Switching Capacity | Resistive: 50 VA, 60 W |
| Inductive: 25 VA, 30 W |
Min Permissible Load | Resistive: 10 µA, 10m VDC |
Outputs - Vent Valve | Inductive: 10 µA, 10m VDC |
| |
Required Vent Valve Type | Normally closed |
Output Voltage |
|
100/240 VAC | 24 VDC |
12 VDC | Input Voltage |
24 VDC | Input Voltage |
Max Operating Current | 2 A |
Max Operating Power | 48 W |
Inputs - Cycle Pressure, 1, 2, 3, Machine Count |
|
Required Switch Type | Normally open (sink, source, or dry contact) |
Sensor Voltage |
|
100/240 VAC | 24 VDC |
12 VDC | Input Voltage |
24 VDC | Input Voltage |
Load Current |
|
100/240 VAC | 22mA @ 24 VDC |
12 VDC | 11mA @ 12 VDC |
24 VDC | 22mA @ 24 VDC |
Maximum Residual Voltage |
|
100/240 VAC | 4 V |
12 VDC | 2 V |
24 VDC | 4 V |
Maximum Off Current |
|
100/240 VAC | 1.5 mA |
12 VDC | 1 mA |
24 VDC | 1.5 mA |
Input Impedance | 1.1 K |
Response Time | 60 ms |
Cycle Rate | 8.0 Hz (50% duty cycle) |
72 | 332305B |