– 30 –

 

Adjustment Items and Procedure

Tools and

Test Points

 

 

 

Signals

 

 

 

 

 

C Board Adjustment

 

 

 

 

 

 

 

1. PLL fo adjustment

 

 

1) WIDE mode

 

 

1.

Select WIDE mode.

* NTSC signal

 

2.

Open the CN5202 pin 1, H.SYNC input.

 

 

3.

Connect *IC5004 pin 2 to the GND (*TP5009) via 100Ω resis-

 

* IC5004 pin 2

 

tance.

 

* TP5009 Jig land

4.

Connect *frequency counter to the pin 1 of *IC5004.

* Frequency counter

* IC5004

5.

Adjust *L5002 so as to satisfy the *specified value.

* Double speed NTSC

 

6.

Input H.SYNC for NT double speed, and confirm the wave-

* Oscilloscope

* TP5007 (RPD2)

 

form at the *TP with *oscilloscope.

 

 

 

 

 

* NTSC signal

 

2)NORMAL mode

1.Select NORMAL mode.

2.Open the CN5202 pin 1, H.SYNC input.

3.

Connect *IC5004 pin 2 to the GND (*TP5009) via 100Ω resis-

 

* IC5004 pin 2

 

tance.

 

* IC5009

4.

Connect *frequency counter to the pin 1 of *IC5004.

* Frequency counter

* IC5004 pin 1

5.

Adjust *L5004 so as to satisfy the *specified value.

 

 

6.

Input H.SYNC for NT double speed

* Double speed NTSC

 

7.

Confirm the waveform at the *TP5004 with *oscilloscope.

* Oscilloscope

* TP5007 (RPD1)

Adjustment Places Illustration Waveforms and Values

* L5002

* 13.67±0.10MHz

 

*

 

 

 

 

 

 

 

 

2.3±0.3 V

 

 

 

 

 

 

 

 

 

 

 

 

 

Use TP5009 as

 

 

 

 

 

reference GND.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* L5004

* 10.22±0.05MHz

 

*

5.0Vp-p

2.39±0.1s

31.78s

Use TP5009 as

reference GND.

KL-W7000/W9000RM-Y980

Page 30
Image 30
Sony KL-W9000 service manual Adjustment Places Illustration Waveforms and Values