– 32 –

 

 

Adjustment Items and Procedure

 

 

Tools and

 

 

 

Test Points

Adjustment Places

Illustration Waveforms and Values

 

 

 

 

 

 

Signals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 IRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 IRE

B

3)

B channel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Using *DC power, apply 0V to *TP5611.

* DC power

 

 

 

* TP5611 [BLBS]

 

 

 

10 IRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* TP5607 is Ref.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

 

 

 

 

 

2.

Connect *oscilloscope to *TP5603, and adjust *RV5605 so

* Oscilloscope

 

 

 

* TP5603 [B-SIG2]

* RV5605 [B. GAIN]

* A : 1.35±0.02Vp-p

 

 

 

that 10 IRE ~ 100 IRE (A) becomes *1.35±0.02Vp-p.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Adjust *RV5601 so that the forward 10 IRE ~ reverse 10 IRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* TP5603 [B-SIG2]

 

* B : 5.90±0.02Vp-p

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

±

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* RV5601 [B. BIAS]

 

 

 

 

 

(B) becomes *5.90 0.02Vp-p at *TP5603.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Confirm that a difference in voltage amplitude of forward 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* TP 5602 [B-SIG1]

 

 

 

 

 

 

IRE ~ 100 IRE and forward 10 IRE ~ reverse 10 IRE between

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* TP5604 [B-SIG3]

 

 

 

 

 

 

waveform at *TP5602,*TP5604 and waveform at *TP5603 is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* TP5603 [B-SIG2]

 

 

 

 

 

 

within ±150mV.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Vcom Adjustment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Using *I2C bus encoder, set the NT-WIDE mode.

*I2C bus encoder

 

 

 

 

 

 

 

 

*Enter NT double speed 10-step signal of *bias 2.2V and amplitude

*

 

 

 

 

 

 

 

2.0 ± 0.02 Vp-p

 

 

 

 

 

 

1.8Vp-p to the CN5201 pins 2~4.

 

 

 

 

 

 

 

 

 

 

 

$

100 IRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 IRE

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.7 ± 0.02 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use TP5201,

 

 

 

 

 

 

 

 

 

 

 

 

 

TP5401 and TP5601

 

 

 

 

 

 

 

 

 

 

 

as reference GND

 

 

 

 

 

 

 

 

 

 

 

respectively.

 

 

 

 

 

 

 

 

 

1. Measure voltage at the *TP5203 with digital voltmeter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* (Value in 1) – 0.60±0.02V

 

 

* Voltmeter

 

 

 

* TP5203 [Rch OUT]

 

 

 

2. Adjust *RV5202 so that the voltage at *TP5205 becomes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* TP5205 [R-Vcom

* RV5202 [R.VCOM]

 

 

 

 

 

*(Value in 1) – 0.60±0.02V.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT]

 

 

 

 

 

3.

Measure voltage at the *TP5403 with digital voltmeter.

* Voltmeter

 

 

 

* TP5403 [Gch OUT]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KL-W7000/W9000RM-Y980

Page 32
Image 32
Sony KL-W9000 service manual Gnd