OP (Others)

 

Item

Register Name

Range

Standard Values

Typical Standard Values

 

Display

 

 

 

 

 

 

0 OSDH

Display H Position

0-63

10 (VIDEO)

7(RGB)

2 Kinds (VIDEO, RGB)

 

1 OSDV

Display V Position

0-63

7 (VIDEO)

7(RGB)

2 Kinds (VIDEO, RGB)

 

2 ASHT

Auto Shut Off

0,1

Not used

 

0: OFF, 1: ON

 

3 CPWR

CH Power ON

 

Not used

 

Not used

 

4 AGCH

AGC Voltage High

0-15

Not used

 

Not used

 

5 AGCL

AGC Voltage Low

0-15

Not used

 

Not used

 

6 DBSS

DBS Category Yes/No

 

Not used

 

Not used

 

7 EDCK

EDTV FULL Mode Detection

0,1

Not used

 

Not used

 

8 AION

AI AUTO

0,1

Not used

 

Not used

 

9 K

Picture Adjusting Variable K

0-7

1

 

Don't set “0” (Actual value is

 

 

 

 

 

 

 

1/8~7/8)

 

10

L

Picture Adjusting Variable L

0-7

0

 

0~7 is converted into 1~8 in actual use.

 

11

LENS

Display only

0

 

Lens focus adj.

 

12

PANEL

0:Green, 1:Red, 2:Blue, 3:White

0-3

 

Panel position adj.

 

13

WHITE

APL

0-1

 

White balance adj. (0: GAIN, 1: BIAS)

 

14

WIND

Display only

0

 

Window signal

 

15

STEP

Display only

0

 

 

00: Normal, 01: Pattern 1,

 

 

 

 

 

 

 

02: Pattern 2

 

16 EDFL

EDTV FULL Detection ON

0,1

Not used

 

Not used

 

17

BC

g_bs_search [0]

1-15

Not used

 

Not used

 

18

TIME

Lamp Counting Timer

 

 

 

Current time count and 0 time are

 

 

 

 

 

 

 

displayed alternately with UP/DOWN

 

FMTL

fh of distinction difference range

0

 

 

± ((3+FHTL) ×0.2) kHz

 

19

 

 

 

29

FVTL

fv of distinction difference range

0

 

 

± (1.0+FVTL) Hz

 

20

 

 

 

21HV1

Threshold of scanning line

0-15

 

 

(505+ (5×HV1)) lines

 

 

distinction (low)

 

 

 

 

 

 

 

 

 

 

 

 

22

HV2

Threshold of scanning line

0-15

 

 

(555+ (5×HV2)) lines

 

 

 

distinction (high)

 

 

 

 

 

23

MINH

fh of the frequency correspond

0-31

 

 

20+ ((3+FHTL) ×0.2) kHz

 

 

 

to MIN

 

 

 

 

 

24

MAXH

fh of the frequency correspond

0-31

 

 

42+ ((3+FHTL) ×0.2) kHz

 

 

 

to MAX

 

 

 

 

 

25

MINV

fv of the frequency correspond

0-15

 

 

(42+MINV) Hz

 

 

 

to MIN

 

 

 

 

 

26

MAXV

fv of the frequency correspond

0-15

 

 

(77+MAXV) Hz

 

 

 

to MAX

 

 

 

 

 

27

FHAG

Equivalence frequency of fh

0-15

 

 

FHAG (20×FHAGms)

 

 

 

changed detection

 

 

 

 

 

28

FVAG

Equivalence frequency of fv

0-15

 

 

FHAG (20×FVAGms)

 

 

 

changed detection

 

 

 

 

 

29

NSAG

Equivalence frequency of

0-15

 

 

Not used

 

 

 

non-signal detection (on signal)

 

 

 

 

 

30

FHMJ

fh difference range of before

0-7

 

 

± ((1+FHMJ) ×0.2) kHz

 

 

 

the signal distinction

 

 

 

 

 

31

FVMJ

fv difference range of before

0-7

 

 

± ((3+FVMJ)

 

 

 

the signal distinction

 

 

 

 

TP (Model Discrimination)

Item Display

Register Name

Range

Standard Values

Typical Standard Values

 

 

 

 

 

0 WIDE

HH

0,1

Not used

 

 

 

 

 

 

1 TIME

TIMER

0,1

0,1

Fan stop time switching

 

 

 

 

0: 10 min (normal), 1: 10 sec

 

 

 

 

 

2 KL37

KL-W7000 model

0,1

0,1

0: KL-W9000 1: KL-W7000

 

 

 

 

 

KL-W7000/W9000