– 34 –

 

Adjustment Items and Procedure

Tools and

Test Points

Adjustment Places Illustration Waveforms and Values

 

 

Signals

 

 

 

 

 

 

 

 

 

 

 

5.

Adjust *RV so that the forward 10 IRE ~ reverse 10 IRE (A) be-

 

 

* RV5402 [GL. BIAS]

 

comes *8.30±0.02Vp-p.

 

 

 

 

 

 

 

 

 

10

IRE

 

Adjustment is no good when 0 IRE ~ 10 IRE voltage is below

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100mV.

 

 

 

 

 

6.Confirm that forward 100 IRE ~ reverse 100 IRE (B) is

*3.45

0.10Vp-p.

 

 

±

 

B

10 IRE

 

 

 

 

 

 

A

 

 

 

10 IRE

100 IRE

* A : 8.30±0.02Vp-p

* B : 3.45±0.10Vp-p

B channel

* Oscilloscope

* TP5603

[B-SIG2]

1.

Connect *oscilloscope to *TP5603.

* DC power

* TP5411

[GLBS]

2.*DC power, apply 3.60±0.02V to *TP5611.

3.Adjust *RV so that 10 IRE ~ 20 IRE becomes *800±20mV. Confirm that 0 IRE ~ 10 IRE voltage is over 7.1V.

20 IRE

10 IRE

* RV5603 [GL. GAIN] * 10 IRE ~20IRE : F800 : 20mV

KL-W7000/W9000RM-Y980

Page 34