6 Pull out the lamp.

For KS-60R200A/50R200A, place your index finger through the hoop of the lamp handle and pull it upwards, while placing your thumb on the dent on the top. Then pull the lamp out.

For KS-70R200A, hold the indents on the top and bottom of the lamp, and pull the lamp straight out.

KS-60R200A/50R200A

8 Put the new lamp into its place.

For KS-60R200A/50R200A, slide it in slowly by pressing the PUSH part of the front corners of the lamp until it stops with a firm clicking sound to lock.

For KS-70R200A, make sure the lamp is securely mounted into the compartment.

KS-60R200A/50R200A

PUSH

PUSH

KS-70R200A

KS-70R200A

Hold this part of the lamp

Notes

The lamp is very hot after use. Never touch the glass portion of the lamp or the non-designated surrounding parts.

After the used lamp has cooled, place it into the empty box of the replacement lamp. Never put the used lamp into a plastic bag.

7 Place the new lamp halfway in. (For KS-60R200A/50R200A)

Follow the gutter in the housing to mount the new lamp securely.

KS-60R200A/50R200A

Hold this part of the lamp

Notes

The lamp compartment is tilted.

To ensure the lamp is securely installed, press the area marked PUSH before closing the lamp cover.

If the lamp is not securely reattached, the self- diagnostic function may be triggered and 1 flashes in red three times (page 14).

KS-60R200A/50R200A KS-70R200A

40 GB