KV-27S40 / 27S45 / 27S65 / 29SL40 / 29SL40A / 29SL40C/ 29SL45 / 29SL65 / 29SL65C/ 29XL40M / 29XL40P / 29XT11A

2. DISPLAY OF STANDBY/TIMER LIGHT FLASH COUNT

2 times

4 times

5 times

Lamp ON 0.3 sec.

Lamp OFF 0.3 sec.

 

 

Lamp OFF

 

 

3 sec.

 

 

 

 

 

Diagnostic Item

Flash Count*

+B overcurrent

2 times

Vertical deflection stopped

4 times

White balance failure

5 times

*One flash count is not used for self-diagnostic.

3.STOPPING THE STANDBY/TIMER FLASH

STANDBY/SLEEP lamp

Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER lamp from flashing.

4. SELF-DIAGNOSTIC SCREEN DISPLAY

For errors with symptoms such as "power sometimes shuts off" or "screen sometimes goes out" that cannot be confirmed, it is pos sible to bring up past occurances of failure for confirmation on the screen:

[To Bring Up Screen Test]

In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:

Screen display channel 5 Sound volume – Power ON

Note that this differs from entering the service mode (sound volume

Self-Diagnostic screen display

SELF DIAGNOSTIC

 

2:

 

0

<-------------

Numeral "0" means that no fault has been detected.

3:

N/A

0

 

 

4:

 

0

 

 

5:

 

1

<-------------

Numeral "1" means a fault has been detected one time only.

101:

N/A

0

 

 

 

 

 

 

 

+

).

5. HANDLING OF SELF-DIAGNOSTIC SCREEN DISPLAY

Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen during repairs. When you have completed the repairs, clear the result display to "0".

Unless the result display is cleared to "0", the self-diagnostic function will not be able to detect subsequent faults after completion of the repairs.

[Clearing the result display]

To clear the result display to "0", press buttons on the remote commander sequentially as shown below when the diagnostic screen is being displayed.

Channel 8 ENTER

[Quitting Self-diagnostic screen]

To quit the entire self-diagnostic screen, turn off the power switch on the remote commander or the main unit.

5

Page 5
Image 5
Sony KV-29XL40P, KV-29SL40C, KV-29SL65C Display of STANDBY/TIMER Light Flash Count, Stopping the STANDBY/TIMER Flash