6. SELF-DIAGNOSTIC CIRCUIT

6. SELF-DIAGNOSTIC CIRCUIT

 

 

IC301

IC541

 

 

IC001

 

 

IC003

 

Y/CHROMA JUNGLE

V.OUT

 

 

SYSTEM

 

 

MEMORY

FROM

21

IK IN

 

 

 

 

IO-BDAT

36

5

B-DAT

CRT

 

 

 

 

 

 

REF

3

17

I-PROT

 

 

 

 

 

 

 

 

 

FROM

 

 

 

 

 

 

 

 

 

 

IC521

18

HP/PROTECT

 

 

 

 

 

 

 

 

PIN 7

 

 

 

 

 

 

 

18

 

 

 

 

SDA

35

 

37

SDAT

O-LED

 

 

 

 

 

 

 

 

 

+B overcurrent (OCP)

Occurs when an overcurrent on the +B(115V) line is detected by pin 18 of IC301. If the voltage to pin 18 of IC301 is less than 1V when V.SYNC is more than seven verticals in a period, the unit will automatically turn off.

Vertical deflection stopped

White balance failure

Occurs when an absence of the vertical deflection pulse is detected by pin 17 of IC001. Power supply will shut down when waveform interval exceeds 2 seconds.

If the RGB levels* do not balance within 2 seconds after the power is turned on, this error will be detected by IC301. TV will stay on, but there will be no picture.

*(Refers to the RGB levels of the AKB detection Ref pulse that detects IK.)