KV-T29SN81

RM-870

3-2. CONVERGENCE

If the V.STAT magnet is moved in the direction of the a and

Preparation :

b arrows, the red, green, and blue points move as shown below.

Before starting this adjustment, adjust the focus, horizontal size, and vertical size.

Minimize the brightness setting.

1

a

 

a

 

b

Provide dot pattern.

 

 

 

 

 

 

 

 

 

 

 

b

 

b

B

 

B

 

 

 

G

 

G

(1)

Horizontal and Vertical Static Convergence

 

 

 

 

 

R

 

R

 

 

 

 

 

 

 

Center dot

2

 

 

 

 

 

 

R

 

 

 

 

 

 

G

a

 

 

 

a

 

 

B

 

 

 

R

G

B

 

R G B

 

 

 

 

 

 

 

H.STAT

V.STAT Magnet

 

b

 

b

 

 

 

 

 

 

 

 

 

 

 

 

B

G

R

 

3

 

 

 

 

a

b

 

b

a

 

RV 702

R

B

 

H.STAT

 

G

G

 

 

RV 701

b

B

R

SCREEN (G2)

 

 

 

 

Cboard

1.(Moving vertically), adjust the V.STAT magnet so that the red, green, and blue points are on top of each other at the center of the screen.

2.(Moving horizontally), adjust the H.STAT VR magnet so that the red, green, and blue points are on top of each other at the center of the screen.

– 15 –

Page 15
Image 15
Sony KV-T29SN81 service manual Horizontal and Vertical Static Convergence