KV-T29SN81
∙ Operation of BMC (Hexapole) Magnet |
| ∙ | Y separation axis correction magnet adjustment. | ||||||
If the red, green and blue dots are not balanced or aligned, then | 1. | Receive the | |||||||
use the BMC magnet to adjust in the manner described below. |
| and [BRIGHTNESS] to “STANDARD” . | |||||||
|
|
|
|
|
|
| 2. | Adjust the Y separation axis correction magnet on the neck | |
R G | B | R | G | B | R | G B |
| assembly so that the horizontal lines at the top and bottom of | |
|
|
|
|
|
|
|
| the screen are straight. |
|
|
|
|
|
|
|
|
| Blue | Red |
|
|
|
|
|
|
| Neck assy | Neck assy | |
R | B | R | G | B |
| G |
|
|
|
G |
|
|
|
|
| ||||
|
|
|
|
| R | B |
| Red |
|
|
|
|
|
|
|
|
| Blue | |
|
|
|
|
|
|
| VM board | VM board |
∙Then use the H.STAT VR to adjust the red, green, and blue dots so that they coincide at the center of screen.
The respective dot position resulting from moving each magnet interact, so be sure to perform adjustment while tracking.
BMC (Hexapole)
Purity
V.STAT
Note: 1) The Red and Blue magnets should be equally far from the horizontal center line.
2)Do not separate the Red and Blue magnets too far. (Less than 8 mm)
– 16 –