xAdjusting the picture’s sharpness manually

(Phase/Pitch) (for PC 2 only)

You can adjust the picture’s sharpness as follows.

1Set the resolution to 1280 × 768 (MFM-HT75W), or 1280 × 1024 (MFM-HT95) on the computer.

2Load the CD-ROM.

3Start the CD-ROM, select the area and model, and display the test pattern.

For Windows

Click [Utility] t [Windows]/[Win Utility.exe].

For Macintosh

Click [Utility] t [Mac]/[Mac Utility].

4Press the MENU button.

The main menu appears on the screen.

5Press the M/m buttons to select (Screen) and press the OK button.

The “Screen” menu appears on the screen.

6Press the M/m buttons to select “Phase” and press the OK button.

The “Phase” adjustment menu appears on the screen.

7Press the M/m buttons until the horizontal stripes are at a minimum.

Adjust so that the horizontal stripes are at a minimum.

8Press the OK button.

The main menu appears on the screen.

If vertical stripes are observed over the entire screen, adjust the pitch using the following procedures.

9Press the M/m buttons to select “Pitch” and press the OK button.

The “Pitch” adjustment menu appears on the screen.

10Press the M/m buttons until the vertical stripes disappear.

Adjust so that the vertical stripes disappear.

11 Click [END] on the screen to turn off the test pattern.

24

xAdjusting the picture’s position manually

(H Center /V Center) (for PC 2 only)

If the picture is not in the center of the screen, adjust the picture’s centering as follows.

1Set the resolution to 1280 × 768 (MFM-HT75W), or 1280 × 1024 (MFM-HT95) on the computer.

2Load the CD-ROM.

3Start the CD-ROM, select the area and model, and display the test pattern.

For Windows

Click [Utility] t [Windows]/[Win Utility.exe].

For Macintosh

Click [Utility] t [Mac]/[Mac Utility].

4Press the MENU button.

The main menu appears on the screen.

5Press the M/m buttons to select (Screen) and press the OK button.

The “Screen” menu appears on the screen.

6Press the M/m buttons to select “H Center” or “V

Center” and press the OK button.

The “H Center” adjustment menu or “V Center” adjustment menu appears on the screen.

7Press the M/m buttons to center the test pattern on the screen.

8Click [END] on the screen to turn off the test pattern.