Ver 1.4 2001. 01

MO Automatic Adjustment item

Mode No.

Description

112

 

 

 

113

MO electrical offset adjustment

114

 

 

 

118

 

221

Lower reflection CD tracking error gain adjustment

223

Lower reflection CD tracking error offset adjustment

 

232

 

236

Lower reflection CD ABCD level adjustment

 

 

244

Lower reflection CD focus gain adjustment

 

 

245

Lower reflection CD tracking gain adjustment

121

MO tracking error gain adjustment

 

 

122

MO tracking error offset adjustment

134

MO TWPP gain adjustment

131

MO double speed read TWPP offset adjustment

 

132

 

136

MO ABCD level adjustment

 

 

144

MO focus gain adjustment

145

MO tracking gain adjustment

 

 

138

MO RF gain adjustment

 

 

434

MO write TWPP gain adjustment

431

MO write TWPP offset adjustment

 

432

 

436

MO write ABCD level adjustment

 

 

445

MO write tracking gain adjustment

411

MO normal speed read TWPP offset adjustment

412

 

 

 

448

32 cluster full recording

141

MO focus bias adjustment

 

 

10.If the result of automatic adjustment is OK, the following dis- play appears in the LCD:

LCD display

141 M O O K

11.If the result of automatic adjustment is NG, the following dis- play appears in the LCD:

LCD display

# # # N G

###: Overall adjustment. NG mode number

12.If NG, set the manual mode. Perform automatic adjustment for the items not accepted. (See page 12)

13.To clear the data in overall adjustment mode, set the manual mode and change the mode number 021 (Res NV) to reset the NV. (See page 12)

14.When both CD and MO overall adjustments are OK, set the manual mode and clear the clock data.

For the microprocessor version 1.20 or later, set the mode num- ber 043 (Resume), and press the X key.

LCD display

043R e s u m e

rPress the X key, historical data clear

043R e s C l r

Note: In step 10, set the clock data to 99Y11M11D11H11M00S, and in step 14, do not set the clock.

[Laser Power Check]

Connection :

laser

power meter

Optical pick-up objective lens

digital voltmeter

MAIN board

Both ends of R1005

Check Method :

1.Select the manual mode of test mode, and set the laser power adjusting mode. (mode number 010)

2.Press the . key continuously until the optical pick-up moves to the most inward track.

3.Open the cover and set the laser power meter on the objective lens of the optical pick-up.

4.Press the N key, and set the laser MO read adjustment mode. (mode number 011)

5.Check that the laser power meter reading is 0.81 ± 0.08 mW.

6.Check that the voltage both ends of resitor R1005 at this time is below 44 mV.

7.Press the N key, and set the laser CD read adjustment mode. (mode number 012)

8.Check that the laser power meter reading is 0.97 ± 0.10 mW.

9.Check that the voltage both ends of resitor R1005 at this time is below 44 mV.

10.Press the N key, and set the laser MO write adjustment mode. (mode number 013)

11.Check that the laser power meter reading is 4.95 ± 0.50 mW.

12.Check that the voltage both ends of resister R1005 at this time is below 80 mV.

13.Press the x key.

14.Release the test mode.

Connecting Location:

– MAIN BOARD (Component Side) –

TP914

(VR)

TP915

(VC)

TP5105

(GND)

– MAIN BOARD (Conductor Side) –

R1005

(+) (–)

– 21 –

– 22 –

Page 21