How to Control the SRP-X700P from External Equipment

REMOTE PARALLEL Terminal

The REMOTE PARALLEL terminal enables the SRP-X700P to be remotely controlled with a simple circuit connected externally to this terminal.

(D-sub 25-pin, female)

Terminal shape

: D-sub 25-pin, female

Recommended cable

: Multi-core shielded cable for data

 

communication

Cable length

: 50 m or less

INPUT terminal

You can set the functions of the respective terminals from the PARALLEL INPUT FUNCTION setup box in the REMOTE screen of the supplied SRP-X700P Manager software.

All faders and sound volume controls can be controlled from a remote location by connecting a variable resistor as shown, in the range of 0 to dB.

You can perform the following operations by adding a make contact.

Input selection of LINE 4 system

Muting

Scene recall

Sound volume adjustment (Up/Down)

Controlling the AV equipment connected to the CONTROL S terminal

Power-ON/STANDBY selection of a projector

OUTPUT terminal

The turning ON conditions of the respective pins of the OUTPUT terminal can be set from the following.

Input selector state of LINE 4 system

Turning ON the OVER and indicators

Turning ON the scene recall button

Generation of the Power-ON/STANDBY command of a projector

You can select the ON conditions from the PARALLEL OUTPUT FUNCTION setup box on the REMOTE screen of the supplied SRP-X700P Manager software.

<Example of input circuit>

SRP-X700P

Input terminal

0 dB

(No. 2 to No. 13)

 

GND

dB

(Nos. 1, 14 and 25)

10 k

 

 

Curve-B variable

 

resistor

SRP-X700P

Input terminal (No. 2 to No. 13)

GND

(Nos. 1, 14 and 25)

<Example of output circuit>

SRP-X700P

40 mA MAX

 

 

 

 

N

Output terminal

(No. 15 to No. 24)

LED

24 V

GND MAX (Nos. 1, 14 and 25)

Notes

Pin No.

Function

 

 

1

GND

 

 

2

INPUT1

 

 

3

INPUT2

 

 

4

INPUT3

 

 

5

INPUT4

 

 

6

INPUT5

 

 

7

INPUT6

 

 

8

INPUT7

 

 

9

INPUT8

 

 

10

INPUT9

 

 

11

INPUT10

 

 

12

INPUT11

 

 

13

INPUT12

 

 

14

GND

 

 

15

OUTPUT1

 

 

16

OUTPUT2

 

 

17

OUTPUT3

 

 

18

OUTPUT4

 

 

19

OUTPUT5

 

 

20

OUTPUT6

 

 

21

OUTPUT7

 

 

22

OUTPUT8

 

 

23

OUTPUT9

 

 

24

OUTPUT10

 

 

25

GND

 

 

Do not apply any reverse voltage across the output terminal.

Do not connect the shield cable of the REMOTE wire and the GND wire to the terminal table or the like. It can cause malfunction and noise.

Install the REMOTE cable away from the dimmer, motor and others.

When the PARALLEL input terminal is used to set the projector power to either the power-ON state or to the power-STANDBY state, the projector power enters the power-ON state when the PARALLEL input is set to ON. The projector power enters the power-STANDBY state when the PARALLEL input is set to OFF. Therefore, use an alternate type switch for power control.