Symptom | Cause and Remedy |
|
|
The TEMP/FAN indicator | • The internal temperature is unusually high. |
lights up. | c Check to see that nothing is blocking the ventilation holes. |
| • The projector is being used at a high altitude. |
| c Ensure that “High Altitude Mode” on the INSTALL SETTING |
| menu is set to “On.” |
|
|
Both the LAMP/COVER | The electrical system has broken down. |
and TEMP/FAN indicators | c Consult with qualified Sony personnel. |
light up. |
|
|
|
Messages List
Warning Messages
Use the list below to check the meaning of the messages displayed on the screen.
Message | Meaning and Remedy |
|
|
High temp.! | Internal temperature is too high. |
Probably use in high | c When using the projector at an altitude of 1,500 m or higher, set |
altitude. Switch to high | “High Altitude Mode” on the INSTALL SETTING menu to “On” |
altitude mode on? Yes V | (see page 32). |
No v | c If this message appears on the screen when using the projector at |
| normal altitudes, check to see if anything is blocking the |
| ventilation holes (exhaust). |
|
|
High temp.! Lamp off in 1 | The internal temperature is too high. |
min. | c Turn off the power. |
| c Check to see that nothing is blocking the ventilation holes. |
|
|
Frequency is out of range! | • This input signal cannot be projected as the frequency is out of the |
| acceptable range of the projector. |
| c Input a signal that is within the range of the frequency. |
| • The resolution setting of the output signal of the computer is too |
| high. |
| c Set the output setting to XGA (see page 15). |
|
|
Please check | You have input an RGB signal from the computer when |
Signal Sel. | Signal Sel.” on the SET SETTING menu is set to “Component.” |
| c Set |
|
|
Please replace the Lamp. | • It is time to replace the lamp. |
| c Replace the lamp (see page 36). |
| c To erase a message, press any key on the control panel of the |
| projector or on the remote commander. |
| • If this message appears again after you replace the lamp, the lamp |
| replacement process is not complete. |
| c Perform the operations in step 8 and 9 on page 37. |
|
|
Please clean the filter. | • It is time to clean the filter. |
| c Clean the filter (see page 38). |
| c To erase a message, press any key on the control panel of the |
| projector or on the remote commander. |
|
|
42 Troubleshooting