Troubleshooting

 

 

 

Others

 

 

 

 

 

Symptom

Cause

Remedy

The LAMP/COVER indicator

The lamp cover is detached or the air

Attach the lamp cover or insert the air filter

flashes.

filter is not inserted securely.

securely (see pages 30 (GB) and 31 (GB)).

 

 

 

The LAMP/COVER indicator

The lamp has reached the end of its life.

Replace the lamp (see page 30 (GB)).

lights up.

 

 

The lamp becomes a high temperature.

Wait for 120 seconds to cool down the lamp and

 

 

 

turn on the power again (see page 20 (GB)).

 

 

 

The TEMP/FAN indicator

The fan is broken.

Consult with qualified Sony personnel.

flashes.

 

 

 

 

 

The TEMP/FAN indicator

The internal temperature is unusually

Check to see if nothing is blocking the ventilation

lights up.

high.

holes.

 

 

 

Both LAMP/COVER and

The electric system failed.

Consult with qualified Sony personnel.

TEMP/FAN indicators light up.

 

 

The INPUT C window does

INPUT C FUNC. is set to OFF.

Set INPUT C FUNC. in the INSTALL SETTING

not appear, or INPUT C

 

menu to ON (see page 27 (GB)).

cannot be selected.

 

 

The menu display does not

The PJ/NETWORK select switch on the

Set the PJ/NETWORK select switch to PJ, then

appear even when you press

Remote Commander is set to

press the MENU key.

the MENU key on the Remote

NETWORK.

 

Commander.

 

 

 

 

 

Warning messages

Use the list below to check the meaning of the messages displayed on the screen.

Message

Meaning

Remedy

 

 

 

High temp.!

Internal temperature is too high.

Turn off the power.

Lamp off in 1 min.

 

Check to see if nothing is blocking the ventilation

 

 

holes.

 

 

 

Frequency is out of range!

This input signal cannot be projected as

Input a signal that is within the range of the

 

the frequency is out of the acceptable

frequency.

 

range of the projector.

 

 

 

 

 

The resolution setting of the output

Set the setting of output to the XGA (see page 15

 

signal of a computer is too high.

(GB)).

 

 

 

Please check INPUT-A

You have input RGB signal from the

Set INPUT-A correctly (see page 26 (GB)).

setting.

computer when INPUT-A in the SET

 

 

SETTING menu is set to COMPONENT

 

 

or VIDEO GBR.

 

Please replace the LAMP.

It is time to replace the lamp.

Please replace the lamp.

 

 

 

Backup Battery Very Low

A backup battery for the network is

Consult with qualified Sony personnel.

 

exhausted.

 

 

 

 

Caution messages

Use the list below to check the meaning of the messages displayed on the screen.

Message

Meaning

Remedy

 

 

 

NO INPUT

No input signal

Check connections (see pages 15 (GB) to 17 (GB)).

 

 

 

Not applicable!

You have pressed the wrong key.

Press the appropriate key.

 

 

 

LENS CONTROL is locked!

LENS CONTROL in the INSTALL

Select YES, or set LENS CONTROL in the

Do you wish to unlock?

SETTING menu is set to OFF.

INSTALL SETTING menu to ON, according to

 

 

your requirement.

 

 

 

33 (GB)