Troubleshooting

 

 

 

 

 

Sound

 

 

 

 

 

 

 

Symptom

Cause

Remedy

 

No Sound.

Cable is disconnected or not connected

Check that the proper connections have been

 

 

properly.

made (see pages 15 (GB) to 18 (GB)).

 

 

 

 

 

 

The sound is cut off.

Press the AUDIO MUTING key to release the

 

 

 

muting function (see page 19 (GB)).

 

When inputting sound through

Monaural sound is being input through

Input stereo sound.

 

AUDIO jack, sound comes

the AUDIO jack.

 

 

through one channel only.

 

 

 

 

 

 

 

 

 

 

 

Others

 

 

 

 

 

 

 

Symptom

Cause

Remedy

 

The LAMP/COVER indicator

The lamp cover or the air filter cover is

Attach the cover securely (see pages 32 (GB) and

 

flashes.

detached.

33 (GB)).

 

 

 

 

 

The LAMP/COVER indicator

The lamp has reached the end of its life.

Replace the lamp (see page 32 (GB)).

 

lights up.

 

 

 

The lamp becomes a high temperature.

Wait for 120 seconds to cool down the lamp and

 

 

 

 

 

turn on the power again (see page 19 (GB)).

 

 

 

 

 

The TEMP/FAN indicator

The fan is broken.

Consult with qualified Sony personnel.

 

flashes.

 

 

 

 

 

 

 

The TEMP/FAN indicator

The internal temperature is unusually

Check to see if nothing is blocking the ventilation

 

lights up.

high.

holes.

 

 

 

 

 

Both LAMP/COVER and

The electric system failed.

Consult with qualified Sony personnel.

 

TEMP/FAN indicators light up.

 

 

 

 

 

 

 

Warning messages

Use the list below to check the meaning of the messages displayed on the screen.

Message

Meaning

Remedy

 

 

 

High temp.!

Internal temperature is too high.

Turn off the power.

Lamp off in 1 min.

 

Check to see if nothing is blocking the ventilation

 

 

holes.

 

 

 

Frequency is out of range!

This input signal cannot be projected as

Input a signal that is within the range of the

 

the frequency is out of the acceptable

frequency.

 

range of the projector.

 

 

 

 

 

The resolution setting of the output

Set the setting of output to the XGA (see page 15

 

signal of a computer is too high.

(GB)).

 

 

 

Please check INPUT-A

You have input RGB signal from the

Set INPUT-A correctly (see page 26 (GB)).

setting.

computer when INPUT-A in the SET

 

 

SETTING menu is set to COMPONENT,

 

 

DTV YPBPR or DTV GBR.

 

Please replace the LAMP.

It is time to replace the lamp.

Please replace the lamp.

 

 

 

Caution messages

Use the list below to check the meaning of the messages displayed on the screen.

Message

Meaning

Remedy

 

 

 

NO INPUT

No input signal

Check connections (see page 15 (GB) to 18 (GB)).

 

 

 

Not applicable!

You have pressed the wrong key.

Press the appropriate key.

 

 

 

SPEAKER OFF

SPEAKER in the SET SETTING menu

Set SPEAKER to ON if necessary (see page 26

 

has been set to OFF.

(GB)).

 

 

 

35 (GB)