Sony XC-ES50/50CE manual ∙ Using trigger pulse width, Specifications of trigger pulse

Models: XC-ES50/50CE

1 39
Download 39 pages 20.81 Kb
Page 11
Image 11

XC-E series

ELECTRONIC SHUTTER

Using trigger pulse width

Set DIP switches 1 to 4 on the rear panel to 0.

An arbitrary shutter speed can be obtained by setting the trigger pulse width to the range of 2 μsec to 250 msec.

Switch

Mode 1

Mode 2

(Non-reset mode)

(Reset mode)

 

 

 

 

1

0

0

2

0

0

3

0

0

4

0

0

5

Frame: 0

/ Field: 1

6

0

0

7

1

0

8

1

1

9

0

0

0

0

0

Exposure time = Trigger pulse width + 97

μsec (EIA)

120

μsec (CCIR)

Note : 1. lt is recommended to set DIP switch 5 for field selection.

(The field selection is about two times in sensitivity as high as the frame selection.)

2.After a trigger pulse is input, a new trigger pulse must not be input before the video signal obtained by the trigger pulse has been output.

1:ON

0:OFF

Specifications of trigger pulse

T

A:4 to 5.0 V

B:0 to 1.0 V

T:2 s to 1/4 s

A

B

T: 2 μs to 1/4 s, 100 μs to 1/4 s when setting the shutter speed using DIP switch

*Input impedance: 10 kW or more

*The voltage and pulse width used are measured at pin 11 of a 12-pin multi-connector on the rear panel.

9

Page 11
Image 11