Sony XC-ES50/50CE manual Specifications of WEN Write ENable Pulse

Models: XC-ES50/50CE

1 39
Download 39 pages 20.81 Kb
Page 12
Image 12

XC-E series

ELECTRONIC SHUTTER

When using a trigger pulse like shown below, set the TRIG polarity selector switch on the rear panel to – :

T

A:4.0 to 5.0 V

B:0 to 2.0 V

A

B

T: 2 s to 1/4 s, 100 s to 1/4 s when setting the shutter speed using DIP switch

*

*

Input impedance: 10 kΩ or more

The voltage and pulse width used are measured at pin 11 of a 12-pin multi-connector on the rear panel.

Specifications of WEN (Write ENable Pulse)

A

B

T

A:5.0 V

B:0 V

T:15.875 ms (XC-ST70), 18.752 ms (XC-ST70CE)

*Output impedance: 10 kΩ or more

10