Sony XC-ES50/50CE manual ∙ Continuous HD input and single VD input

Models: XC-ES50/50CE

1 39
Download 39 pages 20.81 Kb
Page 25
Image 25

XC-E series

TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1 (NON-RESET MODE)

For setting the shutter speed using TRG width

HD/VD input

 

 

 

 

 

Mode transition state

 

 

 

 

 

External input

External trigger

 

 

 

 

*3 Normal operation

inhibition area

 

 

 

External trigger shutter operation

(50 ms)

shutter operation

 

1

 

 

 

 

2

*1

Trigger

 

 

*3 Trigger

 

 

 

 

 

 

 

*2 Exposure

 

*2 Exposure time Te

 

 

*1

 

 

time Te

External HD

 

 

 

 

 

*1

External VD

 

 

 

 

 

 

(Single VD)

4

 

 

 

 

 

*

 

 

min 10 s

 

 

T : T = 10 s to 100 ms

 

 

 

Video out

 

1

 

 

2

WEN

 

 

*5

 

 

 

 

 

 

 

 

 

 

250H

250H

 

250H

 

 

 

(XC-ES50/ES30,

(XC-ES50/ES30,

 

(XC-ES50/ES30,

 

 

 

XC-EI50/EI30)

XC-EI50/EI30)

 

XC-EI50/EI30)

 

 

 

293H

293H

 

293H

 

 

 

(XC-ES50CE/ES30CE, (XC-ES50CE/ES30CE,

(XC-ES50CE/ES30CE,

 

 

 

XC-EI50CE/EI30CE)

XC-EI50CE/EI30CE)

XC-EI50CE/EI30CE)

Continuous HD input and single VD input

*1: *2:

*3:

*4:

*5:

This is a signal input from the outside. Be sure to input both HD and VD signals in this case. Make the phase of the VD signal coincide with the falling edge of the HD signal during input operation.

Exposure time Te Te = Trigger width + 97 μs (XC-ES50/ES30, XC-EI50/EI30),

Te = Trigger width + 120 μs (XC-ES50CE/ES30CE, XC-EI50CE/EI30CE) (The trigger width should be between 2 μs and 1/4 s)

The normal operation state is engaged when the trigger high period exceeds 1/3 sec. After that the external trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the falling edge of a trigger pulse and the subsequent 50 ms period is an external trigger input inhibition area. During the trigger inhibit period, an input trigger may be missed.

Be sure to input an external VD signal between 10 μs and 75 ms from the falling edge of a trigger pulse (as shown by 1 and 2 in the figure). For the input (except described above), the operation cannot be ensured. If the external VD signal is not input under the prescribed conditions, the normal operation is engaged several V after a change in input operation under the prescribed conditions.

When the external trigger shutter mode changes into the normal operation mode, one WEN signal is output.

Note : An image is superimposed when the next exposure ends before the previous image is output.

23

Page 25
Image 25
Sony XC-ES50/50CE manual ∙ Continuous HD input and single VD input