Applications and Setups 5
DG711 and DG511 Pipe Laser User Guide 45
Activating Line
Set/Check Raise 5.4.12
1Simultaneously press the
ON/OFF and the “+” Grade button
to activate Line Set/Check.
Note – For RC502 7-Button
Remote Control users, the ± Grade
enable key must be pressed and the
Red Grade enable LED must be
blinking before the remote will
active Line Set/Check.
2To stop Line Set/Check as it
approaches the line point, press
either Grade button.
3To continue raising grade,
simultaneously press the ON/OFF
and the “+” Grade button.
4If you overshoot and wish to
lower grade, simultaneously press
the ON/OFF and the “-” Grade
button.
5Once the line position is set,
press and release the ON/OFF
button to return the laser beam to
your original grade setting.
Grade enable key