The system will go into a start mode and the feed pump will start shortly after. The system should prime within
Note: The reject light will be on whenever the product water is being rejected or not being made. When the product water is below 750 PPM the green (Good) light will show that water is going to the tank.
Note: You can bypass the purge sequence and initiate a normal start at any time by Pressing both “Auto Run” and “Stop” simultaneously. This will bypass the purge sequence and enable a normal start.
If you must stop the purge sequence for any reason, the control will default back to the beginning of the purging mode to protect your system.
Do not bypass the purge mode unless you are sure that the chemicals are purged from the system or you will permanently damage the membrane.
1.After the purge sequence, the control will alarm with the message “Close pressure relief valve”. Close the valve and proceed by pressing “Auto Run.”
2.The system is now running under pressure and making water. The display will read “purging product water.” This mode dumps the product water overboard for ten min- utes in case there is any residual chemicals in the membrane. Carefully inspect for leaks over the entire system! Shut down the system and repair any leaks you find.
3. The system is now in the operational mode. You may start and run your system as you desire. You will not have to go through the purging mode unless you
4.Check that the system is operating within its normal parameters. Compare with the chart on the next page.
19