Feed Pump Relocation
If you do not have adequate space to install the feed pump inlet module it is possible to re- move and relocate the feed pump. Before you install the module, disconnect the hose that connects the feed pump to the module plumbing. Remove the cooling fan and the heat sink from the pump. Both are friction fits with no fasteners. Remove the 4 machine screws hold- ing the pump to the module.
Cooling fan
Machine Screws
Heat sink
With the pump on a flat surface. Remove the three screws that hold the pump head on. See Fig1
Reinstall the screws and tighten firmly. See Fig3
Now the feed pump may be installed where you wish. Do not install with the pump head over the motor in- case of leaks. Wire size may have to be increased if wire runs are longer.
Fig 1
Fig 2 | Fig 3 |
9