Stovax 7051Bl, 7053lG, 7008 walls next to hearths, Site Requirements, Requirement for the walls

Models: 7051lG 7053 7053Bl 7008Bl 7008 7008lG 7053lG 7051 7051Bl

1 30
Download 30 pages 32.76 Kb
Page 16
Image 16
walls next to hearths

SITE REQUIREMENTS

walls next to hearths

Solid, non-combustible material e.g. masonry or concrete

H

150mm

minimum

C

Thickness W

C

150mm

minimum

PR7227

Position of Appliance & Hearth in relation to walls

Requirement for the walls

 

 

 

 

Distance of hearth from wall

Distance of Appliance to wall

Min thickness of Wall

Min height of wall

'C'

 

'W'

'H'

 

 

 

 

0mm

0mm - 50mm

200mm

Height of appliance + 300mm

 

 

 

Or

 

 

 

 

 

 

1200mm from the hearth (take largest

0mm

51mm - 300mm

75mm

dimension)

 

 

 

 

0 - 150mm

150mm +

75mm

1200mm

 

 

 

 

150mm +

300mm +

No Minimum Requirement

 

 

 

 

Suitable clearance should be allowed around the stove to enable the correct fitting and maintenance of the stove. Any clearances should be confirmed by making a site survey and a physical check of wall thickness and dimensions.

16

Page 16
Image 16
Stovax 7053, 7051Bl walls next to hearths, Site Requirements, Requirement for the walls, Distance of Appliance to wall