INSTALLATION INSTRUCTIONS

PR8009

The Flue must be installed in accordance with manufacturers instructions.

Flue Pipe 915mm (3ft)

Size

Stovax Part No.

*5"

4502

6"

4602

Self tappping screw at rear

The Flue must be installed in accordance with manufacturers instructions.

Seal Collar with Fire Cement

Self Tapping Screw

 

 

Tee

 

 

 

 

Size

Stovax Part No.

 

 

 

 

5"

4516

 

 

 

 

6"

(4616)*

 

 

 

Cap

PR7228

Seal flue collar with Fire Cement

PR7230

To chimney connection as detailed in building regulations

600mm min

1000mm max unsupported

To chimney connection as detailed in building regulation

Elbow with access cover

Size Stovax Part No.

5" 4512

6"* 4612

Flue Pipe 915mm (3ft)

Size Stovax Part No.

600mm min

1000mm max unsupported

Elbow with access cover

Size Stovax Part No.

5" 4512

6"* 4612

Flue Pipe 915mm (3ft)

Size Stovax Part No.

5" 4502

6"* 4602

5" 4502

6"* 4602

PR7229

PR7226

1.3Rear flue pipe installation

• Insert a tee into the flue collar

The tee piece is used as cleaning access.

• Lift appliance into position

Take care not to damage the hearth finish.

Level using adjustable bolts, see picture 1

Connect tee to the chimney using flue pipe

Secure with self tapping screw

Seal the connecting joints

Do not use a 90˚ elbow to make this connection

2.REMOVAL OF THE LOG GUARD

2.1To remove the Log guard:

Lift Log Guard clear of the supporting brackets

Rotate to clear the sides of the door opening.

Do not use appliance without the log guard in position.

3.FITTING & REMOVAL OF FIREBRICKS (BRUNEL 1A ONLY)

3.1Remove the firebricks as part of the routine maintenance. This can be carried out without the use of tools.

3.2Allow the appliance to cool fully before removing firebricks.

20

Page 20
Image 20
Stovax 7053lG, 7051 Removal of the LOG Guard, Rear flue pipe installation, Do not use a 90˚ elbow to make this connection