USER INSTRUCTIONS
Airwash
Closed Open
Primary Air
Open Closed
Secondary | Closed |
|
Combustion |
| |
|
| |
Control (not 1A) Open | PR7225a |
DOOR HANDLE
1.12Use a protective gloved hand to operate. See Diagram 4
DO NOT OPEN THE DOOR WITH BARE HANDS
Door Tool:
Lift and Pull
forward to open
WARNING
Properly installed, operated and maintained this appliance will not emit fumes into the room.
Occasional fumes from
Persistent fume emission is potentially dangerous and must not be tolerated.
If fume emission does persist:
• Open doors and windows to ventilate the room
•Allow fire to burn out or safely dispose of fuel from the appliance
•Check for chimney blockage and clean if required
•Do not attempt to relight until the cause of the emission has been identified and corrected
If necessary seek expert advice.
•All open flued appliances can be affected by temporary atmospheric conditions which may allow fumes to enter the house. Because of this it is recommended that an electronic carbon monoxide detector conforming to BSEN50291 be fitted and maintained.
2.USING THE Appliance FOR THE FIRST TIME
2.1To allow the appliance to settle and fixing glues and paint to fully cure:
•Operate the appliance at a low output for first few days
2.2Do not touch the paint during the first period of use.
2.3During this time the appliance may give off some unpleasant odours:
•Keep the room well ventilated to avoid a
3.RECOMMENDED FUELS
3.1Wood Logs:
•Burn only seasoned timber with a moisture content of less than 20%
| Wood Length |
Appliance | Wood Length |
Brunel 1A | 250mmm |
Brunel 2CB | 330mm |
Brunel 3CB | 400mm |
•Dry cut wood for 12 to 18 months before use
Poor quality timber:
— Causes low combustion efficiency
— Produces harmful condensation
— Reduces effectiveness of the airwash and life of the appliance
Do not burn construction timber, painted, impregnated
/treated wood, manufactured board products or pallet wood.