PRE-INSTALLATION CHECKS
1. Flue
Model |
| Brunel1a | Brunel2CB | Brunel3CB | ||
Brunel 1a - 7008/7008BL/7008LG |
| |||||
Brunel 2CB - 7051/7051BL/7051LG |
| |||||
|
|
|
| |||
Brunel 3CB - 7053/7053BL/7053LG |
|
|
|
| ||
|
|
|
|
|
| |
|
| mm | 150 | 150 | 150 | |
| Without Liner System Round (diameter) |
|
|
|
| |
| inch | 6 | 6 | 6 | ||
|
| |||||
|
|
|
|
|
| |
| Without Liner System (square) minimum | mm | 135 | 135 | 135 | |
Flue/Chimney size |
|
|
|
| ||
dimension | inch | 51/2 | 51/2 | 51/2 | ||
| ||||||
|
| |||||
| With Liner or Factory made System | mm | 150† | 150 | 150 | |
| (diameter) |
|
|
|
| |
| inch | 6† | 6 | 6 | ||
| installed in accordance with manufacturers instructions | |||||
|
|
|
|
|
| |
|
|
|
|
|
| |
|
| m | 4 | 4 | 4 | |
Flue/Chimney Minimum Height* |
|
|
|
|
| |
| feet | 13 | 13 | 13 | ||
|
| |||||
|
|
|
|
|
|
*When measured from the top of the stove to the top of the flue, with no horizontal sections
and a maximum of 4 bends with angles of less than 45°
‡May be 125mm (5”) if burning low volatiles (smokeless) fuels approved for use in Smoke Control Areas. See web site http://uksmokecontrolareas.co.uk for more information about approved fuels.
2.ADDITIONAL VENTILATION
2.1Additional ventilation is required to comply with the requirements of the Building Regulations. This must be provided using a permanently open air vent, of the size listed, which is positioned so that it is not liable to be blocked both inside and outside the building.
2.2Extractor fans or cooker hoods must not be placed in the same room or space as this can cause the appliance to emit fumes into the room.
2.3If any of these checks reveal problems do not proceed with the fitting of the appliance until they have been rectified.
Model |
| Brunel 1a | Brunel 2CB | Brunel 3CB |
Brunel 1a - 7008/7008BL/7008LG |
| |||
Brunel 2CB - 7051/7051BL/7051LG |
| |||
Brunel 3CB - 7053/7053BL/7053LG |
| |||
|
| |||
|
|
|
|
|
| mm2 | 0 | 550 | 1100 |
Additional Ventilation | cm2 | 0 | 5.5 | 11.0 |
| In2 | 0 | 0.85 | 1.7 |
17