TECHNICAL SPECIFICATION
brunel
Model |
|
| Brunel1a | Brunel2CB | Brunel3CB | |
Brunel 1a - 7008/7008BL/7008LG |
|
| ||||
Brunel 2CB - 7051/7051BL/7051LG |
|
| ||||
|
|
|
|
| ||
Brunel 3CB - 7053/7053BL/7053LG |
|
|
|
|
| |
|
|
|
|
|
| |
| Wood | kW | 4.0 | 6.0 | 7.0 | |
Nominal Heat Output |
|
|
|
|
| |
Solid Fuel | kW | 4.0 | 6.0 | 7.0 | ||
| ||||||
|
|
|
|
|
| |
|
| mm Wg | 1.25 | 1.25 | 1.25 | |
Flue Draught @ Nominal Heat Output | All Fuels |
|
|
|
| |
inch Wg | 0.05 | 0.05 | 0.05 | |||
|
| |||||
|
|
|
|
|
| |
| Wood | g/s | 3.3 | 5.5 | 5.2 | |
Flue Gas Mass Flow |
|
|
|
|
| |
Solid Fuel | g/s | 3.4 | 5.8 | 4.5 | ||
| ||||||
|
|
|
|
|
| |
| Wood | °C | 396 | 360 | 442 | |
Flue Gas Temperature @ Spigot/Socket |
|
|
|
|
| |
Solid Fuel | °C | 369 | 360 | 442 | ||
| ||||||
|
|
|
|
|
| |
|
| mm | 125 | 150 | 150 | |
Flue Outlet Size (Top or Rear Option) |
|
|
|
|
| |
| inch | 5 | 6 | 6 | ||
|
| |||||
|
|
|
|
|
| |
|
|
|
|
|
| |
Weight |
| Kg | 62 | 90 | 120 | |
|
|
|
|
|
|
Recommended Fuels
Wood | Seasoned Wood (less than 20% moisture content) | |
|
| |
Solid Fuel | Briquette Smokeless Fuel Suitable for Closed Appliances. (Ancit- | |
| ||
|
|
As tested to the requirements of EN 13240 for intermittent operation.
1.standard features
•Primary Air (under grate air for full
•Airwash (for wood burning / clean glass)
•Adjustable Secondary Combustion Control - 2 & 3 CB only
(to ensure complete burning of flue gases)
•Riddling grate system for clean
•Top or rear flue exit option
2. packing list
•User Instructions
•Installer Instructions
•Guarantee card
•Door handle tool
12