Stovax Ceramica Manhattan Wood Stove Flame Failure Functional Check, Ignition Functional Check

Models: Ceramica Manhattan Wood Stove

1 27
Download 27 pages 20.9 Kb
Page 21
Image 21
FLAME FAILURE FUNCTIONAL CHECK 3

FLAME FAILURE FUNCTIONAL CHECK 3

PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE

Ensure there is no debris around the pilot assembly, (e.g. coal, soot

etc.) which could short the spark, clear the area.

IGNITION FUNCTIONAL CHECK 2

NO SPARK

Ensure there is no debris around the pilot assembly, (e.g. coal, soot

etc.) which could short the spark, clear the area.

Light the pilot and keep the control knob pushed in at least 10

seconds before letting go.

 

NO

 

YES

With the fire

With the pilot

Will the pilot stay

running on full, is

 

 

lit?

 

 

running, is the gas

 

 

 

 

 

 

 

 

the gas at the

 

 

 

 

 

pressure stated on NO

 

 

 

 

NO pressure stated on

Problem is with the

From Ignition Fault Finding

Chart Part 1.

Operate the valve to light the NO pilot, does the valve ‘click’? Manual background

YES

Consult the Users Instructions,

retry.

Is the valve being operated

properly?

YES

21

the databadge?

 

 

pipework or fittings

 

the databadge?

 

 

 

 

 

 

 

 

 

which lead to the

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

fire. Correct and

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

retry.

Run for no more

 

 

 

 

than 60 seconds,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

turn off, time

YES

 

 

 

 

 

 

 

 

Is the pilot flame of

 

 

 

 

 

 

interval until mag

 

 

Is thermocouple

NO

the correct length?

 

 

 

 

 

connection good in

 

 

unit shuts with a

 

See diagram 1 on

 

 

 

 

 

 

 

 

 

 

 

 

back of valve?

 

 

click. Is this greater

 

page 19.

 

 

 

 

 

 

 

 

 

 

 

than 7 seconds?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the

 

 

Tighten the

 

NO

 

 

 

 

 

connection and

 

 

 

 

thermocouple.

 

 

 

 

 

 

 

 

 

retry.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

Is the pilot burner horizontal?

See diagram 1 Servicing

Requirements.

YES

Has ignition lead become detached or is connection poor?

NO

Remove the electrode lead from electrode with insulated pliers. Hold the tip 4mm from the pilot pipework, is there a spark when the valve ‘clicks’?

NO

NO

YES

Reset the electrode gap, retry.

Correct and retry.

Check the defective or

damaged control knob spindle or cam operation. Check for correct location of piezo components. Correct and retry.

 

 

 

 

 

 

YES

Run for 60 seconds,

 

 

Change the pilot

 

Will pilot stay alight?

 

 

 

 

 

 

turn off, time

 

 

unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

interval until mag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

unit shuts with a

 

 

 

 

 

 

NO

 

 

 

 

 

 

click. Is this greater

 

 

 

 

Change mag unit.

 

 

 

 

 

 

 

 

 

 

than 7 seconds?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the electrode wire detached from the piezo in the valve?

NO

Replace the combined lead,

retry.

Replace the pilot unit.

YES

Remove the electrode lead from the piezo. Operate the valve. Does a spark jump from the piezo to the valve body?

YES

Replace the electrode lead

and retry.

Page 21
Image 21
Stovax Ceramica Manhattan Wood Stove manual Flame Failure Functional Check, Ignition Functional Check