TECHNICAL SPECIFICATION
RIVA APPLIANCE
MODEL: |
|
|
|
|
|
|
| |
Riva Plus Small |
|
| SmallPlusRiva |
|
| LargePlusRiva | ||
Riva Plus Large |
|
|
|
| ||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
Nominal Heat Output | Wood | kW | 5.0 |
|
|
| 11.0 | |
|
|
|
|
|
|
| ||
| Solid Fuel | kW | 5.0 |
|
|
| 11.0 | |
|
|
|
|
|
|
|
| |
|
| mm Wg | 1.5 |
|
|
| 1.5 | |
|
|
|
|
|
|
|
| |
Flue Draught at Nominal Heat Output | All | inch Wg | 0.05 |
|
|
| 0.05 | |
|
|
|
|
|
|
|
| |
|
| Pa | 12.5 |
|
|
| 12.5 | |
|
|
|
|
|
|
|
| |
Flue Gas Mass Flow | Wood | g/s | 4.5 |
|
|
| 7.9 | |
|
|
|
|
|
|
| ||
Solid Fuel | g/s | 4.4 |
|
|
| 6.0 | ||
|
|
|
| |||||
|
|
|
|
|
|
|
| |
Flue Gas Temperature at Spigot / Socket | Wood | C | 290 |
|
|
| 326 | |
|
|
|
|
|
|
| ||
Solid Fuel | C | 251 |
|
|
| 408 | ||
|
|
|
| |||||
|
|
|
|
|
|
|
| |
Flue Outlet Six (Top/Rear Option) |
| mm | 128 |
|
|
| 153 | |
|
|
|
|
|
|
| ||
| inch | 5 |
|
|
| 6 | ||
|
|
|
|
| ||||
|
|
|
|
|
|
|
| |
Weight |
| Kg | 95 |
|
|
| 175 | |
|
|
|
|
|
|
|
| |
Recommended Fuels | Wood | Seasoned wood (less than 20% moisture content) |
| |||||
|
|
|
|
|
|
| ||
Solid Fuel | Briquette smokeless fuel suitable for closed appliances | |||||||
| ||||||||
|
|
|
| |||||
|
|
|
|
| ||||
As tested to the requirements of EN 13240 for intermittent operation |
|
| ||||||
|
|
|
|
|
|
|
|
1.STANDARD FEATURES
•Primary air
•Airwash
•Secondary air control (to ensure complete burning of flue gases)
•Riddling grate system for clean
•Top or rear flue exit option
2. PACKING LIST
•Instructions
•Guarantee card
•Flue Collar
•Tools: Hex Keys
•Gloves
•Blanking Plate
•Door Tool - Double Door Only
•Ash Pan Tool -
•Accessories Catalogue
•Thermic Seal
•Riddling Tool -
12