MAINTENANCE and SERVICING
•Press the new Stovax rope into the locating groove, placing the joint in the middle of the lower edge of the door
•Refit the door and close the door to apply pressure to the new rope
•Leave the appliance closed for at least 12 hours before lighting the appliance and using at a low output for approximately one day
8.2Using the appliance with a damaged door seal can cause dangerous fumes to enter the room, or the appliance to over fire, resulting in damage.
9.ADJUSTING DOOR HINGES
9.1To maintain the safe use of your appliance, you may need to adjust the door hinges to ensure the door closes safely and correctly.
9.2To complete this operation:
•Open the door to give access to the fixed part of the door hinge as shown
Inside nut is prevented from turning
Fixing Nut Lock Nut
PR7087
PR8116
•Use a 19mm A/F spanner to loosen the fixing nuts
•Reposition the hinge blocks to achieve a correct fit
This may require several adjustments to find the correct position.
28