Stovax Large Wood & Multi-fuel manual Pre-Installationchecks, Flue, Additional Ventilation

Models: Medium Wood & Multi-fuel Small Wood & Multi-fuel Large Wood & Multi-fuel Midi Wood & Multi-fuel

1 32
Download 32 pages 48.92 Kb
Page 17
Image 17
PRE-INSTALLATION CHECKS

PRE-INSTALLATION CHECKS

1. Flue

MODEL:

 

 

TraditionalSmall SMM/RVP-SMW

 

 

TraditionalLarge LAM/RVP-LAW

Riva Plus Small RVP-SMM/RVP-SMW

 

 

 

Riva Plus Large RVP-LAM/RVP-LAW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Riva RVP-

 

 

Riva RVP-

 

 

 

 

 

 

 

 

 

 

Without flue liner Round (diameter)

mm

150

 

 

150

 

 

 

 

 

 

 

 

 

 

 

inch

6

 

 

6

 

 

 

 

 

 

 

 

 

 

Without flue liner system Square

mm

135

 

 

135

 

 

 

 

 

 

 

 

 

inch

51/2

 

 

51/2

Flue/Chimney Size

 

(diameter)

 

 

 

With liner or Factory made system

mm

†150

 

 

†150

 

 

 

 

 

 

(diameter)

 

 

 

 

 

 

 

installed in accordance with manufacturer's instructions

inch

†6

 

 

†6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue/Chimney

 

All products

metre

4.5

 

 

4.5

 

 

 

 

 

 

 

feet

13

 

 

13

(*minimum height)

 

 

 

 

 

 

 

 

 

 

 

 

* When measured from the top of the stove to the top of the flue, with no horizontal sections and a maximum of 4 bends with angles of less than 45o

†May be 125mm (5") if only burning low volatiles (smokeless) fuels approved for use in Smoke Control Areas.

See website http://uksmokecontrolareas.co.uk for more information about approved fueld

2. ADDITIONAL VENTILATION

2.1Additional ventilation is required to comply with the requirements of the Building Regulations. This must be provided using a permanently open air vent, of the size listed, which is positioned so that it is not liable to be blocked both inside and outside the building.

2.2Extractor fans or cooker hoods must not be placed in the same room or space as this can cause the appliance to emit fumes into the room.

2.3If any of these checks reveal problems do not proceed with the fitting of the appliance until they have been rectified.

MODEL:

Traditional Small SMM/RVP-SMW

Traditional Large LAM/RVP-LAW

Riva Plus Small RVP-SMM/RVP-SMW

Riva Plus Large RVP-LAM/RVP-LAW

 

 

 

 

Riva RVP-

Riva RVP-

 

 

 

 

 

mm2

NONE

3300

Additional Ventilation

cm2

NONE

33.0

in2

NONE

5.12

 

17