Sub-Zero UC-24CI4 Electrical Requirements, Plumbing Requirements, MODEL UC-24CI, Site Preparation

Models: UC-24CI4

1 16
Download 16 pages 59.03 Kb
Page 6
Image 6
Electrical Requirements

Site Preparation

6

 

 

Electrical Requirements

The electrical supply should be located within the shaded area shown in the illustration below. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance is required.

IMPORTANT NOTE: The electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall.

Model UC-24RO is designed and safe for use in outdoor applications. When installed outdoors, a ground fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock. A GFCI is not recommended for use with other undercounter models and may cause interruption of operation.

Do not use an extension cord or two-prong adapter. Electrical ground is required on this appliance.

Plumbing Requirements

MODEL UC-24CI

For model UC-24CI, the water supply line for the ice maker should be located within the shaded area shown in the illustration below. Connect the water line from the ice maker water valve to the house water supply line. Use an easily accessible shut-off valve between the water supply and the unit. Do not use self-piercing valves. A saddle valve kit is available from your authorized Sub-Zero dealer.

A line filter is required when water conditions have a high sediment content. The ice maker operates on water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar).

A reverse osmosis system can be used, provided there is a consistent water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar) supplied to the water valve at all times. A copper line is not recommended for this application.

IMPORTANT NOTE: In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently.

Electrical Requirements

Power Supply

115 V AC, 60 Hz

Circuit Breaker

15 amp

Receptacle

3-prong grounding-type

 

 

Plumbing Requirements

Water Supply Line

1/4" OD copper, braided stainless steel

 

 

or PEX tubing

Water Pressure

 

20–100 psi (1.4–6.9 bar)

Excess Water Line for Connection

26" (660) min

LEFT SIDE

OF OPENING

2" (51)

151/2"

(394)

3" (76)

FRONT VIEW

Location of electrical supply.

SHADED AREA

EXTENDS 1/2" (13)

FROM BACK WALL

2" (51)

Plumbing RequirementsMODEL UC-24CI 151/2" Manual backgroundManual background

(394)

3" (76)

FRONT VIEW

Location of water supply.