Sub-Zero UC-24CI4 manual Installation, Level The Unit, Position The Unit, Install Kickplate

Models: UC-24CI4

1 16
Download 16 pages 59.03 Kb
Page 8
Image 8
Installation

Undercounter Installation

8

 

 

Installation

IMPORTANT NOTE: If the undercounter unit has been laid on its back or side, you must allow the unit to stand upright for a minimum of 24 hours before connecting power.

With the undercounter unit near the installation opening, plug the power cord into the electrical outlet. With power applied to the unit, check for lighting and cooling. Once you are satisfied that the unit is operating properly, shut off power to the electrical outlet at the circuit breaker and proceed.

LEVEL THE UNIT

Level the unit before sliding it into position. Leveling cannot be completed with the unit pushed back in the installation opening.

Using an adjustable wrench or pliers, turn each of the four leveling legs clockwise to raise the unit and counterclock- wise to lower the unit. For the location of the leveling legs, refer to the illustration.

To reduce the possibility of the unit tipping forward, the front leveling legs must be in contact with the floor.

POSITION THE UNIT

WATER LINE CONNECTION (MODEL UC-24CI)

For model UC-24CI, connect the plastic tubing from the ice maker to the house water supply line with the fitting connection kit, provided. Check all water line fittings for leaks.

Purge the water line prior to final connection to the unit. This will remove any debris that may be present in the tubing from installing the new water line.

IMPORTANT NOTE: Let your customer know that the ice maker will not produce ice immediately, and that the first few batches of ice produced should be discarded. Allow 24 hours for proper ice production.

IMPORTANT NOTE: Water lines must not be exposed to freezing temperatures. Exposure could cause damage to the unit and home.

INSTALL KICKPLATE

Install the kickplate using the two #10 x 1/2" stainless steel screws that are provided with the kickplate. Refer to the illustration below.

The kickplate must be removed for servicing. The floor cannot interfere with removal. Do not cover the louvered section of the kickplate to allow proper air circulation.

Turn power back on to the electrical outlet.

Slide the undercounter unit back into position in the installation opening. Make sure it contacts the anti-tip bracket for a stable installation.

The undercounter unit provides the best access to its contents when the front surface of the door panel extends out from surrounding cabinets approximately 1/4" (6).

LEVELING LEGS

KICKPLATE

Location of leveling legs.

Kickplate installation.

Page 8
Image 8
Sub-Zero UC-24CI4 Installation, Level The Unit, Position The Unit, WATER LINE CONNECTION MODEL UC-24CI, Install Kickplate