Ice Machine Installation | 8 |
|
|
Installation Requirements
•Installation must allow removal of the ice machine for cleaning and service. Service diagnostics are per- formed from the top of the ice machine.
•If the ice machine is installed in a corner, the door swing may be limited due to handle contact with the adjacent wall or cabinet. A 90° door stop is provided.
•Do not install the ice machine within 18" (457) of a trash container, compactor or recycling container.
•Do not install the ice machine near
•The installation location must not obstruct airflow through the kickplate.
•The installation location must be free of airborne and other contaminants.
•The ambient air temperature must be between 50°F (10°C) and 100°F (38°C) for indoor models and between 50°F (10°C) and 110°F (43°C) for outdoor models.
IMPORTANT NOTE: Failure to follow installation require- ments of the ice machine may affect warranty coverage.
The ice machine must be protected if it will be exposed to ambient temperatures below 32°F (0°C). Component failure caused by exposure to freezing temperatures is not covered by the warranty.
Installation
Before moving the ice machine into position, make sure all opening dimensions, electrical and plumbing requirements are complete and accurate. The floor under the ice machine must be at the same level as the surrounding finished floor.
Move the ice maker into position near the installation opening. Remove and discard all packing materials. Remove the literature packet and drain hose from inside the ice machine. The bin thermostat clip is shipped with tape holding it in position. Remove the tape. Also, remove the tape securing the water shutters.
Although the ice machine has been designed to be serviced in place, in some cases it may be necessary to slide the unit out for service or cleaning. The installation must allow for removal of the unit.
Before moving the ice machine into position, protect any finished flooring to avoid damage.