![](/images/new-backgrounds/1332182/33218213x1.webp)
Overview
Fibre Channel Architecture
The Sun StorEdge 3510 FC array RAID controller has six fibre channels that can support 1 or 2 Gb data transfer speeds. RAID controller channels 0, 1, 4, and 5 are normally designated for connection to hosts or Fibre Channel switches. RAID controller channels 2 and 3 are dedicated drive channels.
In a dual RAID controller configuration, both RAID controllers have the same host channel designators, due to the architecture of the loops within the chassis. Each host channel of the top RAID controller shares a loop with the matching host channel on the bottom RAID controller. For example, channel 0 of the top RAID controller shares the same loop as channel 0 of the bottom RAID controller. This provides four distinct loops for connectivity with two ports per loop. The individual loops provide LUN failover without causing HBA path failover in the event of a controller failure.
Each I/O board has two ports designated as disk drive loops. These ports connect to the internal
A single RAID controller configuration is slightly different. The lower I/O board has drive channels but does not have host channels. Overall, the same number of loops are available, but with half as many host channel ports.
Fibre Channel Protocols
The Sun StorEdge 3510 FC array supports
Best Practices for the Sun StorEdge 3510 FC Array 3