environment. For environments with different server configurations, choose the solution that best matches the servers whose applications are
General Configuration Considerations
The
It is preferable to use
The Sun StorEdge 3510 FC array is extremely flexible, but when designing storage solutions remember to keep them as simple as possible. Keep the following suggestions in mind when designing the configuration of a Sun StorEdge 3510 FC storage system:
■Prior to creating logical drives and mapping them to host channels, set the appropriate cache optimization, Fibre Channel protocol and controller channel IDs. Reset the controller after these configuration parameters have been set.
■For best performance and RAS, create logical drives across expansion units.
■Use either local or global spare drives when creating logical drives. Any free drive can be designated as a spare and more than one drive can be used as a spare.
■Use dual pathing for each LUN and use Sun StorEdge Traffic Manager software to provide load balancing across controller ports for increased performance.
■The maximum number of LUNs when using
■After completing the configuration of the Sun StorEdge 3510 FC array, the configuration should be saved using the firmware “save nvram to disks” menu option and the Sun StorEdge Configuration Service Console's “save configuration” utility.
Best Practices for the Sun StorEdge 3510 FC Array 11