Ultra Enterprise

Connect Ultra 2

1422 mm/56-inch

expansion cabinet

data center

power cord here

and StorEdge

expansion cabinet

 

expansion cabinet

 

power sequencer

power sequencer

 

 

FIGURE 1-5AC Power Sequencers—Ultra 2 Power Connector

To connect the power cord:

1.Gain access to the AC power sequencers.

See the documentation that came with the expansion cabinet.

2.Route the power cable from the Ultra 2 host under the expansion cabinet frame on the same side as the power sequencer.

3.Connect the power cord from the Ultra 2 host into the top power connector of either power sequencer (FIGURE 1-5).

The power connectors are located on the other side of the power sequencer from the main switch.

4.Reassemble the expansion cabinet.

See the documentation that you received with the expansion cabinet.

1-8Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999